AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010LF1W)

The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010LF1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$67.25 $72.60Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-10 Combination Unit (GFC30010LF1W)

The AirTAC GFC series is a two-piece set made up of a filter regulator and a separate lubricator, covering filtration, regulation and oil-mist lubrication for a compressed-air circuit. This GFC30010LF1W is the 300 size with 3/8 in PT ports and the W option: a 5 um filter element instead of the standard 40 um, for finer removal of water and particulate ahead of the regulator. It uses a differential-pressure bowl drain, the low-pressure (L) regulator variant and a square gauge with an MPa scale.

This is a genuine AirTAC part; the G series runs in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and drain types, filter grades, gauges and threads are all catalogue options. Flow for the series is published as curves, not a single rating, so ask us and we will confirm the applicable datasheet figures for your application on request.

AirTAC GFC300-10 Combination Unit (GFC30010LF1W) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010LF1W)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010LF1W)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010LF1W) Is Used

science

Laboratory pneumatic test rigs

Supplying the pneumatic actuators and air bearings on a laboratory test rig, where the 5 um element gives finer particulate removal ahead of the regulator to protect the more sensitive components under test.

air

Air-jet cleaning stations on a production line

Feeding the air-jet blow-off stations on a production line, where the two-unit set cleans and regulates the supply and the lubricator is set appropriately for jets that must not carry excess oil to the product.

view_module

Electronics assembly workstations

Preparing air for the vacuum pickups and small cylinders at electronics assembly workstations, where finer filtration helps keep sensitive boards and tooling clear of airborne particulate.

Is the AirTAC GFC300-10 Combination Unit (GFC30010LF1W) the Right Set?

Select the W variant when the standard 40 um element is too coarse for your downstream equipment; the finer 5 um element suits applications that are more sensitive to particulate. Expect a somewhat higher pressure differential across the element and drain the bowl appropriately; the differential-pressure drain fitted here is the default, with manual and automatic drains available as options. The 300 size with 3/8 in PT ports sits mid-range; step to 400/600 for more flow or 200 for compact circuits. Thread is PT as standard with G (BSPP) and NPT orderable; a bracket is included by default. Since flow appears only as curves in the catalogue, ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010LF1W) FAQ

There is no single rated flow figure to quote: AirTAC publishes flow for the G series as performance curves. Tell us your supply pressure, set pressure and required flow, and we will confirm the relevant datasheet curve for this 3/8 in model on request before you commit.

Choose W when the equipment downstream is sensitive to finer particulate, such as instrument-grade pneumatics, test rigs or precision tooling. The standard 40 um grade remains the default on this family, and the W grade is simply the orderable option on the same body, so you can specify either per position.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010LF1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30010LF1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.