verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010LNW)

The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010LNW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC300-10 Combination Unit (GFC30010LNW)

GFC30010LNW is a genuine AirTAC G-series two-unit set that pairs a filter regulator with a lubricator, so one order covers water and particulate removal, pressure regulation and oil-mist lubrication on a single 3/8 in PT ported line. In this code the 300 size, the fine 5 um filter element (W), the default differential-pressure drain, the low-pressure type designation (L) and the omission of a gauge (N) are all fixed at ordering. Because it carries the L low-pressure type code, we confirm the exact regulator adjustment range for this variant from the datasheet on request.

The medium is compressed air, maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C (non-freezing). At size 300 the bowls are polycarbonate (PC); only the 600 size uses aluminium alloy bowls. The GFC family also comes in 200, 400 and 600 sizes and in configurations with automatic or manual drains, the standard 40 um element, embedded square or external round gauges on MPa, psi or bar scales, and G (BSPP) or NPT threads as catalogue options. Flow is published as curves rather than a single rated figure, so we confirm sizing and full datasheet figures on request.

AirTAC GFC300-10 Combination Unit (GFC30010LNW) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010LNW)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010LNW)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010LNW) Is Used

science

Laboratory test-bench air preparation

Conditions the air feeding pneumatic actuators and jigs on a lab test bench, where the low-pressure type, fine 5 um element and oil-mist lubrication suit sensitive bench equipment on a 3/8 in circuit.

view_module

Packaging machine valve islands

Prepares the supply to valve islands on a cartoning or wrapping line: water and fine particles are stripped out, the pressure is held at the set point and the lubricator carries oil mist to the pick-and-place cylinders.

conveyor_belt

Conveyor clamping and air-jet circuits

Feeds clamp cylinders and air jets along a conveyor assembly line, keeping moisture and scale out of the valves while the lubricator protects cylinders through continuous cycling.

Is the AirTAC GFC300-10 Combination Unit (GFC30010LNW) the Right Set?

Step through the sizes (200 to 600, 1/8 in to 1 in ports) to match your pipe bore and air demand - the right step depends on flow, so we check the published flow curves against your application before you order. Drain choice matters day to day: the differential-pressure drain in this code needs no setting but relies on flow to purge, the automatic option drains continuously, and the manual option needs a routine bleed and widens the regulator adjustment range on GFC sets. This code's 5 um element suits finer point-of-use air than the standard 40 um. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and the N code means no gauge - add a gauge code if you need local indication. Ask us to confirm sizing against the flow curves for your line before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010LNW) FAQ

AirTAC publishes G-series capacity as flow curves, not as a single rated figure, so we do not quote one number. Send us your line pressure and air demand and we will confirm the sizing and the full datasheet figures on request before you order.

The N in GFC30010LNW means the set comes without a gauge. Other codes in the GFC300 series include the embedded square gauge or an external round gauge with MPa, psi or bar scales - tell us which indication you need and we will point you to the right code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010LNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC30010LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.