The AirTAC AirTAC GFC300-10 Combination Unit (GFC30010MNK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series combines a filter-regulator and a lubricator in one two-unit set, so a single mounting delivers filtered, regulated and oil-mist lubricated compressed air. This 300-size configuration is ported PT3/8 with a manual drain on the filter bowl, standard 40 um filtration, no gauge, a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), and a reverse (check) valve fitted.
It is a genuine AirTAC part for compressed air, rated to 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C, with a PC (polycarbonate) bowl at this size. The G series spans sizes 200 to 600 with ports from 1/8 to 1 inch; flow is published as curves rather than a single rating, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFC300-10 Combination Unit (GFC30010MNK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-10 |
| Build order | Filter regulator first, lubricator last |
Feeds filtered, regulated and lubricated air to pneumatic clamping cylinders on a machining cell, with the check (reverse) valve part of the circuit as coded.
Supplies tool air at a bench or trim line where operators run impact drivers and nutrunners that need both steady regulated pressure and oil mist.
Conditions the air driving pick-and-place cylinders and grippers on a carton or bottling line, with a manual drain that fits a maintenance round.
Size 300 is the PT3/8 step in the G range; move to 400 or 200 if your line size or demand points elsewhere - flow is published as curves, not a single rating, so send us your flow requirement and we will confirm sizing from the datasheet before you order. The M in this code means a manual drain: choose it where bowl draining is part of a regular routine, or specify automatic or the differential-pressure default for less attention. The W position is blank, so filtration is the standard 40 um; add W for the 5 um option. This code also specifies no gauge and a fitted check (reverse) valve. PT thread is standard on this model, with G (BSPP) and NPT available as catalogue options.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Tell us your required flow and line size and we will confirm the right size from the datasheet on request before you order.
The M in GFC30010MNK decodes to a manual drain on the filter bowl, which suits sites where draining is done on a schedule. AirTAC also offers automatic drains and a differential-pressure drain (the default) on the same family, so you can match the drain to how the machine is attended.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.