The AirTAC AirTAC GFC300-15 Combination Unit (GFC30015C1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC30015C1 is a two-unit air treatment set: a filter regulator paired with a lubricator, so one order covers filtration, pressure regulation and oil-mist lubrication of your compressed air line. This 300-size set has PT1/2 ports, the standard 40 um filter element, a differential-pressure drain on the filter bowl, and a round pressure gauge on an MPa scale fitted to the regulator.
This is a genuine AirTAC part. The G-series set is offered in 200, 300, 400 and 600 sizes with a choice of port, thread, drain type and filter grade; flow figures are published as curves rather than a single rating, so we confirm datasheet numbers on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015C1) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Mounted ahead of a CNC machining centre's air manifold, the set filters machining debris and condensate from the shop supply, holds a steady regulator setting for actuator circuits, and meters oil mist to spindle clamps and tool-changer cylinders.
On a packaging conveyor line, the filter regulator keeps sorting and stopper cylinders supplied with clean air at a stable pressure while the lubricator feeds the pneumatic grippers that handle cartons all shift.
Feeding the pneumatic jet and doffing circuits of an air-jet loom, the two-unit set removes line moisture and lint-laden particles, regulates branch pressure, and lubricates the loom's cylinder banks from one PT1/2 connection.
Start with size and port: the 300 size with 1/2" PT ports suits mid-range supply lines, and stepping up to 400 or 600 increases port size and flow capacity. The 40 um element is the standard grade; choose the W suffix for a 5 um element where finer filtration is needed. Drain is differential-pressure here, with automatic (A) and manual (M) versions available in the family.
This C1 configuration carries a round gauge with an MPa scale. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options, and the mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
AirTAC publishes flow for the G-series as performance curves, not as a single rated figure, so there is no one flow number we can quote. Tell us your application and line conditions and we will confirm the flow and sizing data from the datasheet on request.
GFC is the two-unit family (filter regulator plus lubricator), 300 is the size, 15 is the 1/2" port, and C1 means a round external pressure gauge on an MPa scale. The default configuration also carries the standard 40 um filter element and a differential-pressure drain; 5 um (W) and automatic or manual drain variants are available in the same family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.