
The AirTAC AirTAC GFC300-15 Combination Unit (GFC30015C1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC30015C1W is a two-unit air treatment set: a filter regulator plus a lubricator in one order. The W suffix specifies the 5 um filter element instead of the 40 um standard, giving finer particulate removal ahead of sensitive pneumatic equipment. This 300-size set has PT1/2 ports, a differential-pressure drain and a round pressure gauge on an MPa scale.
This is a genuine AirTAC part. The G-series two-unit set spans 200, 300, 400 and 600 sizes with options for port, thread, drain type and filter grade. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015C1W) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
On a lab test bench running pneumatic sample fixtures, the 5 um element keeps fine particulates out of precision test cylinders and transducers, while the regulator sets test pressure and the lubricator services the clamping actuators.
Supplying SMT pick-and-place modules on an electronics line, the set's 5 um filtration protects the fine air bearings and vacuum ejectors, with regulation and oil mist for the placement head cylinders from one PT1/2 feed.
Feeding a pneumatic tube transport station's diverters and door actuators, the set delivers finely filtered, regulated and lubricated air, helping the 5 um element limit wear on the small-bore transfer valves.
Pick the W (5 um) grade over the standard 40 um when the downstream equipment needs finer filtration, such as instrumentation or precision cylinders. The 300 size with PT1/2 ports suits mid-range supply lines; step to 400 or 600 for larger ports and more flow. Drain is differential-pressure here, with automatic (A) and manual (M) versions available.
The C1 configuration carries a round gauge with an MPa scale. Thread is PT as standard, with G (BSPP) and NPT as catalogue options, and the mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
There is no single rated flow to quote: AirTAC publishes G-series flow as performance curves rather than one figure. Share your operating pressure and demand and we will confirm the flow data from the datasheet on request.
The W suffix changes the filter element from the standard 40 um to 5 um, for finer particulate removal ahead of sensitive equipment. The rest of the decode is unchanged: two-unit filter regulator plus lubricator, 300 size, PT1/2 ports, differential-pressure drain, and a round MPa-scale gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.