The AirTAC AirTAC GFC300-15 Combination Unit (GFC30015F3W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC30015F3W is a two-unit compressed-air treatment set combining a filter regulator with a separate lubricator: it removes water and particulate, regulates downstream pressure and meters oil mist in one supply. The W suffix specifies the 5 um filter element instead of the 40 um standard, giving finer protection for sensitive valves and actuators. This size 300 unit has a PT1/2 in. port, differential-pressure drain, embedded square gauge scaled in bar, 1.0 MPa (145 psi) maximum working pressure and a 0.15-0.9 MPa (20-130 psi) regulator range.
This is a genuine AirTAC part from the G-series, offered in sizes 200 through 600 with 1/8 to 1 in. ports, G (BSPP) or NPT threads, a choice of drains and both filter grades. Flow is published as curves rather than a single rating, so ask us to confirm sizing and full datasheet figures on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015F3W) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Supplying pilot-air to solenoid and process valves where the 5 um element keeps fine spool and orifice passages clear, while the regulator holds a stable set pressure and the lubricator serves the downstream cylinders.
Conditioning air on a laboratory or pilot-scale automation skid: clean, finely filtered air for grippers and small actuators, with regulated pressure for repeatable test conditions and oil mist for continuous cycling.
Feeding spray guns and coating applicators, where finer filtration helps keep finish quality consistent, the regulator sets atomising pressure, and the lubricator is set for air motors and triggering valves.
Choose this code when your line needs the finer 5 um element - the standard code without W gives 40 um for general plant air. Size 300 with a PT1/2 in. port sits mid-range in the G-series; step to 400 or 600 for larger ports and more flow. The differential-pressure drain handles condensate automatically at high differential; manual (M) and automatic (A) drains are catalogue options. The square gauge reads in bar, with psi or MPa scales and the external round gauge available. PT is the standard thread, G (BSPP) and NPT are order options, and a bracket is included.
Flow is published as curves, not a single rated figure, so have us confirm sizing against the datasheet for your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
Flow for the G-series is published as characteristic curves rather than a single rated number, so we do not quote a figure as a rating. Share your line pressure and demand and we will confirm the sizing from the datasheet on request before you place the order.
The W suffix changes only the filter grade, from the 40 um standard to 5 um, giving finer protection for precision valves and instruments. Everything else stays the same: size 300, PT1/2 in. port, differential-pressure drain, square bar-scale gauge, lubricator included and 1.0 MPa maximum working pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.