The AirTAC AirTAC GFC300-15 Combination Unit (GFC30015LC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC30015LC1 is a two-unit compressed-air treatment set: a filter regulator paired with a separate lubricator, providing filtration, pressure regulation and oil-mist lubrication in one supply. The L suffix marks the low-pressure regulator type, intended where only a reduced set pressure is needed, and the C1 suffix specifies the external round pressure gauge scaled in MPa. This size 300 configuration has a PT1/2 in. port, standard 40 um filter element and differential-pressure drain; maximum working pressure is 1.0 MPa (145 psi). The exact adjustment range of the low-pressure type differs from the standard unit, so confirm it on request.
This is a genuine AirTAC part from the G-series, which runs in sizes 200, 300, 400 and 600 with 1/8 to 1 in. ports, G (BSPP) or NPT thread options, a choice of drains, both filter grades and standard or low-pressure regulator types. Flow is published as curves, not a single rating, so ask us to confirm sizing and datasheet figures on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015LC1) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Running a bank of light-duty clamp or ejector cylinders that work at reduced pressure: the low-pressure regulator holds the gentle set point, the 40 um filter keeps the valves clean and the lubricator feeds the actuators.
Supplying diverters, gates and pushers on a sorting conveyor where delicate products need low regulated pressure, plus clean filtered air and oil mist to keep the small cylinders cycling smoothly.
Conditioning supply air to textile or converting machinery with low-pressure jets and tensioning cylinders: filtration removes water and fibre-loaded particulate while the regulator and lubricator serve the actuation circuit.
Specify this code when the downstream equipment only needs a low set pressure - the L type regulator is the defining choice, and its adjustment range should be confirmed against your application before ordering. Size 300 with a PT1/2 in. port is the mid step of the G-series; move to size 200 for smaller ports or 400 and 600 for more flow. The differential-pressure drain empties the bowl automatically at high differential; manual (M) and automatic (A) are options. The round external gauge reads in MPa, with psi or bar scales and the embedded square gauge available. PT is standard thread, G (BSPP) and NPT are order options.
Flow is published as curves, not a single rated figure, so ask us to confirm sizing against the datasheet before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
AirTAC publishes flow for the G-series as characteristic curves, so there is no single rated figure to quote. Send us your working pressure, set pressure and air demand and we will confirm sizing against the datasheet on request before you order.
L marks the low-pressure regulator type, chosen where downstream equipment operates at a reduced set pressure rather than full line pressure. Its adjustment range differs from the standard type, so confirm the range with us for your application. The C1 suffix means the external round gauge with an MPa scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.