The AirTAC AirTAC GFC300-15 Combination Unit (GFC30015MNK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC30015MNK is a two-unit air preparation set - a filter-regulator plus a separate lubricator - in the 300 size with PT1/2 ports and a reverse (check) valve fitted, shown by the K code. The filter bowl is drained manually, filtration is the standard 40 um element, and the regulator in this manual-drain configuration adjusts over 0.05-0.9 MPa (7-130 psi). The lubricator meters oil mist into the regulated air for downstream actuators and tools. Maximum working pressure is 1.0 MPa (145 psi), the bowl is PC (polycarbonate) as is standard at size 300, and operating temperature is -5 to 70 C (non-freezing). No gauge is fitted on this variant.
This is a genuine AirTAC part. The GFC series is offered in sizes 200 through 600 with drain-type, filter-grade, gauge, reverse-valve and G/NPT thread options listed in the catalogue. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet flow data for your circuit.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015MNK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Conditions air feeding clamping cylinders on a press-fit fixture station. The fitted reverse (check) valve is included for circuits where the designer wants check-valve protection in the supply line, while the set filters, regulates and lubricates the clamp air.
Prepares the air entering a directional-valve manifold on a machine skid: 40 um filtration ahead of a regulated, lubricated supply keeps spool valves clean and moving freely, with manual bowl draining tied to the shift maintenance round.
Serves the PT1/2 air drop feeding doffing and yarn-threading actuators on a textile machine. The regulator holds the set pressure, the lubricator mists oil to the actuators, and the K-code check valve is fitted as specified for the machine build.
Use this code when your decodable requirements are: 300 size, PT1/2 port, manual drain, standard 40 um filtration, no gauge, and a reverse (check) valve fitted - the K suffix is the only difference from the plain GFC30015MN. If you do not need backflow protection in the circuit, the non-K code is the equivalent unit without the valve. Larger sizes (400, 600) step up port and flow capacity; the W code switches the element to 5 um. Thread is PT as standard with G (BSPP) and NPT variants orderable.
Because flow is published as curves and not as a single rating, send us your application details and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
Rated flow is published as curves, not as one rated number, so the honest way to size it is against your actual demand. Send us your flow, pressure and duty cycle and we will confirm the GFC30015MNK data from the AirTAC datasheet on request.
K means a reverse (check) valve is fitted to the unit. It is the same two-unit filter-regulator-plus-lubricator set as the GFC30015MN otherwise - PT1/2, size 300, manual drain, 40 um element, no gauge. For the valve's exact behaviour in your circuit, ask us for the datasheet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.