AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-10 Combination Unit (GFC40010AC1)

The AirTAC AirTAC GFC400-10 Combination Unit (GFC40010AC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.83 $117.27Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-10 drain, gauge and thread option on one page All GFC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-10 Combination Unit (GFC40010AC1)

The AirTAC GFC series pairs a filter regulator with a lubricator in a two-piece set covering filtration, pressure regulation and oil-mist lubrication. This GFC40010AC1 is the size 400 unit with 3/8 in PT ports, the standard 40 um filter element and an automatic drain that empties the filter bowl without daily attention. An external round pressure gauge with MPa scale is included, and the regulator adjusts outlet pressure across 0.15-0.9 MPa (20-130 psi). It runs on compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, with polycarbonate bowls on both sections.

This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 in to 1 in, plus G (BSPP) and NPT thread variants, manual or differential drains, a 5 um element option, gauge choices and a check-valve option, so a matching set can be ordered for most lines. Flow is published as curves rather than a single rating; ask us to confirm the datasheet figures and sizing for your application.

AirTAC GFC400-10 Combination Unit (GFC40010AC1) Technical Specifications

ModelAirTAC GFC400-10 Combination Unit (GFC40010AC1)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-10 Combination Unit (GFC40010AC1)

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-10 Combination Unit (GFC40010AC1) Is Used

precision_manufacturing

Pick-and-place robotics

Point-of-use treatment for pick-and-place robot cells: the regulator sets cylinder and gripper pressure, the lubricator feeds the actuator air, and the round MPa gauge lets technicians verify the setting at a glance.

factory

Assembly plant air drops

Fits assembly-station air drops where the automatic drain clears condensate from the bowl on lines that run through breaks and shift changes without anyone bleeding the bowl by hand.

local_shipping

Truck service bay

Feeds impact wrenches, air jacks and inflation stations in a commercial-vehicle service bay, with the 3/8 in PT ports matching typical shop drop hoses and the gauge showing regulated tool pressure.

Is the AirTAC GFC400-10 Combination Unit (GFC40010AC1) the Right Set?

Size 400 with 3/8 in PT ports suits medium plant-air and machine supply lines; move to size 300 for compact branches or size 600 where larger ports are needed. This version takes the automatic drain (A) for hands-off condensate removal, while the standard differential-pressure drain and the manual drain (M) remain order choices. The element is the standard 40 um grade; specify W for 5 um. The external round gauge reads in MPa; square gauges and psi or bar scales can be ordered. PT is the standard thread, with G (BSPP) and NPT as catalogue options.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

AirTAC GFC400-10 Combination Unit (GFC40010AC1) FAQ

There is no single rated flow figure: AirTAC publishes G-series performance as flow curves. Send us your working pressure and air consumption and we will confirm the correct size from the datasheet on request.

A specifies an automatic drain, which empties the filter bowl without manual attention. The alternatives are the standard differential-pressure drain or a manual drain (M) - note that manual-drain versions regulate across 0.05-0.9 MPa (7-130 psi), while this automatic-drain set regulates 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-10 Combination Unit (GFC40010AC1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40010AC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.