The AirTAC AirTAC GFC400-10 Combination Unit (GFC40010NK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC40010NK is a genuine AirTAC GFC two-unit air preparation set: a filter regulator and a lubricator supplied as a matched pair for one 3/8 in PT ported line, with a reverse (check) valve fitted as indicated by the K suffix. The filter-regulator section removes water and particulate down to the standard 40 um grade and holds downstream pressure anywhere in the 0.15-0.9 MPa (20-130 psi) adjustment window that applies with the differential-pressure drain fitted. The N suffix means no gauge is included. Size 400 handles compressed air only, with a maximum inlet pressure of 1.0 MPa (145 psi), a working range of -5 to 70 C (non-freezing), and a polycarbonate bowl on the filter-regulator section.
This is a genuine AirTAC part in the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and thread options PT, G (BSPP) and NPT. Filter grade (40 um standard, 5 um optional), drain type, gauge and reverse-check valve are all orderable variants. AirTAC publishes flow as curves rather than a single rated figure, so we confirm the datasheet and flow data for your application on request.
| Model | AirTAC GFC400-10 Combination Unit (GFC40010NK) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT3/8" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-10 |
| Build order | Filter regulator first, lubricator last |
Prepares air for the ejector and part-blow-off circuits on a stamping press line, with the check valve helping hold the set downstream pressure in the circuit.
Conditions air for the gripper and lift actuators in an AS/RS storage cell, filtering, regulating and lubricating on a single 3/8 in supply.
Feeds pilot air to actuated process valves on a plant skid, keeping the set regulated pressure and a conditioned air supply to the pilot ports.
Size 400 with a 3/8 in PT port sits mid-range in the G series; confirm your flow requirement with us before stepping between sizes, because AirTAC publishes flow as curves and not as a single rating. The K in this code means a reverse/check valve is fitted, which is the difference from the plain GFC40010N. The 40 um element is standard; the W variant gives 5 um filtration. No gauge is fitted on this code, and gauge variants with different scales exist in the family. PT is the standard thread, with G (BSPP) and NPT as catalogue thread options. Ask us to confirm sizing and the datasheet against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not state a number here. Share your supply pressure and demand profile and we will confirm the datasheet and curve figures for this exact set on request before you order.
K indicates that a reverse (check) valve is fitted in this set. The otherwise identical code without K is supplied without the check valve, and gauge, filter grade and drain variants are also orderable in the family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.