The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015AF2) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC40015AF2 is a two-unit air-treatment set combining a filter regulator with a lubricator: it strips water and particulate, regulates downstream pressure, and delivers oil mist. This version is the 400 size with PT1/2 ports, an automatic drain, the standard 40 um filter element, and an embedded square gauge scaled in psi. The regulator adjusts from 0.15-0.9 MPa (20-130 psi) with the automatic drain, and maximum inlet pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the G series, which runs from size 200 to 600 with optional G (BSPP) and NPT threads, manual or differential-pressure drains, 5 um elements, and gauge scale choices. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet and sizing for your application on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015AF2) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Regulating and lubricating the clamp and ejector cylinders on a stamping press's periphery, with the psi gauge matching the plant's US-style instrument standard.
Conditioning supply to the vacuum-blowoff and flap-fold cylinders on a carton-forming machine, where general 40 um filtration and steady regulation keep the cycle repeatable.
Feeding a 1/2-inch shop-air drop that serves impact tools and hose reels, combining water removal, pressure setting and oil mist at the point of use.
The 400 size with PT1/2 ports suits circuits specified at 1/2 inch where demand is beyond the 200/300 bodies - match the curve to your flow. The automatic drain clears condensate without daily attention. The standard 40 um element is the economical choice for general-purpose actuation; step to the W variant for 5 um where equipment needs finer filtration. The square psi gauge suits US-specified panels. PT is the standard thread; G (BSPP) and NPT are catalogue options to order.
Flow is published as curves, not a single rating, so give us your flow and pressure conditions and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes G-series flow as performance curves rather than one rated figure, so we do not quote a single number. Share your required flow and pressure and we will confirm the sizing from the datasheet on request before you order.
The F2 code specifies the embedded square gauge with a psi scale, suiting panels specified in US units. The alternative F1 variant carries the same square gauge scaled in MPa, and both are catalogue choices across the regulator-equipped G-series sets.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.