The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015ALC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC40015ALC1 is an AirTAC G-series two-unit air-treatment set: a GFR400 filter-regulator paired with a GL400 lubricator, covering filtration, pressure regulation and oil-mist lubrication in two pieces. This configuration is sized for 1/2 in. ports with PT thread, uses an automatic drain on the filter bowl, carries the standard 40 um filter element, and is the low-pressure (L) type. It comes with a round external gauge reading in MPa. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. At size 400 the bowls on both units are PC (polycarbonate).
This is a genuine AirTAC part from the GFC series. The same set is offered in sizes 200, 300, 400 and 600 with a choice of PT, G (BSPP) or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, and round or square gauges in MPa, psi or bar scales. AirTAC publishes flow for these units as curves rather than a single rated figure, so we confirm flow and full datasheet details for your application on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015ALC1) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Feeding filtered, regulated and lubricated air to directional control valves on an automated packaging line from a 1/2 in. take-off point, keeping the low-pressure circuit conditioned before the manifold.
Conditioning supply air for the clamp and pusher actuators along a bottling conveyor, with oil mist carried downstream so cylinder seals run on lubricated air.
A treatment point at a machine shop assembly drop, filtering and regulating the shop main before it feeds air tools and clamping fixtures on the cell.
Size and port are the first decision: 400 with 1/2 in. PT suits mid-size plant air take-offs; step up to 600 (1 in.) or down to 300 or 200 if your line volume differs - match the step to required flow, which we confirm from the flow curves before you order. Drain choice: automatic empties the filter bowl without operator attention; manual gives deliberate control; the differential-pressure default triggers on pressure drop. Filter grade: 40 um is standard for general plant air, 5 um (W) where finer particulate protection matters. Gauge: this set carries a round gauge on the 1 (MPa) scale; square-gauge (F) variants and psi or bar scales are orderable. Thread: PT is standard; G and NPT are catalogue options.
As the low-pressure (L) type, the catalogue adjustment range quoted for the automatic-drain version is 0.15-0.9 MPa (20-130 psi); we confirm the L-type adjustment limits against the datasheet on request before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for the GFC series as curves, not as a single rated figure, so we do not quote a number here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet on request before you order.
C selects the round external gauge and 1 sets its scale to MPa. If you prefer the square gauge instead, or a psi (2) or bar (3) scale, the F2/F3 or C2/C3 variants of the same set are orderable - just ask us to confirm availability for your configuration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.