verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015ALC1)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015ALC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.83 $117.27Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015ALC1)

GFC40015ALC1 is an AirTAC G-series two-unit air-treatment set: a GFR400 filter-regulator paired with a GL400 lubricator, covering filtration, pressure regulation and oil-mist lubrication in two pieces. This configuration is sized for 1/2 in. ports with PT thread, uses an automatic drain on the filter bowl, carries the standard 40 um filter element, and is the low-pressure (L) type. It comes with a round external gauge reading in MPa. Maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. At size 400 the bowls on both units are PC (polycarbonate).

This is a genuine AirTAC part from the GFC series. The same set is offered in sizes 200, 300, 400 and 600 with a choice of PT, G (BSPP) or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, and round or square gauges in MPa, psi or bar scales. AirTAC publishes flow for these units as curves rather than a single rated figure, so we confirm flow and full datasheet details for your application on request.

AirTAC GFC400-15 Combination Unit (GFC40015ALC1) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015ALC1)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015ALC1)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015ALC1) Is Used

valve

Pneumatic valve manifold supply

Feeding filtered, regulated and lubricated air to directional control valves on an automated packaging line from a 1/2 in. take-off point, keeping the low-pressure circuit conditioned before the manifold.

conveyor_belt

Conveyor clamp and pusher cylinders

Conditioning supply air for the clamp and pusher actuators along a bottling conveyor, with oil mist carried downstream so cylinder seals run on lubricated air.

factory

Assembly-cell air drop

A treatment point at a machine shop assembly drop, filtering and regulating the shop main before it feeds air tools and clamping fixtures on the cell.

Is the AirTAC GFC400-15 Combination Unit (GFC40015ALC1) the Right Set?

Size and port are the first decision: 400 with 1/2 in. PT suits mid-size plant air take-offs; step up to 600 (1 in.) or down to 300 or 200 if your line volume differs - match the step to required flow, which we confirm from the flow curves before you order. Drain choice: automatic empties the filter bowl without operator attention; manual gives deliberate control; the differential-pressure default triggers on pressure drop. Filter grade: 40 um is standard for general plant air, 5 um (W) where finer particulate protection matters. Gauge: this set carries a round gauge on the 1 (MPa) scale; square-gauge (F) variants and psi or bar scales are orderable. Thread: PT is standard; G and NPT are catalogue options.

As the low-pressure (L) type, the catalogue adjustment range quoted for the automatic-drain version is 0.15-0.9 MPa (20-130 psi); we confirm the L-type adjustment limits against the datasheet on request before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015ALC1) FAQ

AirTAC publishes flow for the GFC series as curves, not as a single rated figure, so we do not quote a number here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet on request before you order.

C selects the round external gauge and 1 sets its scale to MPa. If you prefer the square gauge instead, or a psi (2) or bar (3) scale, the F2/F3 or C2/C3 variants of the same set are orderable - just ask us to confirm availability for your configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015ALC1)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015ALC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.