verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015ALNW)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015ALNW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$105.18 $111.48Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015ALNW)

The AirTAC GFC series is a two-unit air-treatment set: a filter-regulator paired with a lubricator, so one assembly removes water and particulate, holds a set downstream pressure and meters oil mist into the air line. This unit is size 400 with a PT1/2 port (PT thread is the standard; G and NPT are catalogue options), an automatic drain on the filter bowl so condensate is discharged without operator attention, the optional 5 um filter element (code W) in place of the 40 um standard, and no gauge fitted (code N). It is the low-pressure (L) type, intended for reduced outlet settings; confirm its exact low-pressure adjustment range with us on request.

This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing); the size 400 filter bowl is PC (polycarbonate). Across the G series you can step size and port from 200 to 600, choose differential-pressure, automatic or manual drains, order the 40 um standard element or the 5 um (W) option, add gauge and bracket options and select PT, G (BSPP) or NPT threads. Flow for this size is published as curves rather than a single rated figure, so we confirm datasheet and sizing values on request.

AirTAC GFC400-15 Combination Unit (GFC40015ALNW) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015ALNW)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015ALNW)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015ALNW) Is Used

science

Laboratory automation air

Treating air to the pneumatic actuators of an automated pipetting and plate-handling station, where the 5 um element cuts finer particles than the 40 um standard ahead of the lab's small control valves.

build

Pneumatic clamping fixtures

Regulating and lubricating air to swing clamps on a machining-centre fixture table; the 5 um element suits the compact clamping valves and the low-pressure type keeps clamp pressure settings gentle.

view_module

Carton-erector valve train

Feeding the valve manifold of a carton-erecting machine on a packaging line; filtered, regulated air at a low set pressure drives the folding cylinders, with the 5 um element protecting the machine's control valves.

Is the AirTAC GFC400-15 Combination Unit (GFC40015ALNW) the Right Set?

Real choices in this family: step the size and port (200/300/400/600; here 400 with a PT1/2 port) against the flow your line needs; pick the drain - automatic on this unit, with differential-pressure (default) and manual also available; the W here has already selected the finer 5 um element over the 40 um standard; thread is PT as the standard with G (BSPP) and NPT orderable; and a gauge can be specified since none is fitted. The low-pressure (L) type suits reduced outlet settings - confirm its range with us. Flow is published as curves, not one rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015ALNW) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so no one number is quoted here. Give us your line pressure, set pressure and demand and we will confirm the sizing from the datasheet on request.

The W in GFC40015ALNW selects the optional 5 um element instead of the 40 um standard. Choose 5 um where downstream valves, cylinders or processes are more particle-sensitive; the standard 40 um element suits general plant air duty.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015ALNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015ALNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.