The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015AN) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air-treatment set: a filter-regulator paired with a lubricator, so one assembly removes water and particulate, holds a set downstream pressure and meters oil mist into the air line. This unit is size 400 with a PT1/2 port (PT thread is the standard; G and NPT are catalogue options), an automatic drain on the filter bowl so condensate is discharged without operator attention, the standard 40 um filter element, and no gauge fitted (code N). It is the standard regulator type: with the automatic drain, outlet pressure adjusts over 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing); the size 400 filter bowl is PC (polycarbonate). Across the G series you can step size and port from 200 to 600, choose differential-pressure, automatic or manual drains, order the 5 um (W) element instead of 40 um, add gauge and bracket options and select PT, G (BSPP) or NPT threads. Flow for this size is published as curves rather than a single rated figure, so we confirm datasheet and sizing values on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015AN) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Conditioning plant air for tool-change cylinders, chip augers and air blasts on a vertical machining centre; the 1/2" PT port matches the machine's main air drop and the automatic drain handles condensate.
Running stopper and gate cylinders on a bottling conveyor; the filter-regulator section keeps the pressure steady over 0.15-0.9 MPa (20-130 psi) while the lubricator mists oil to the cylinder seals.
Supplying a bench-mounted pneumatic press in an electronics assembly cell; the 40 um element guards the control valve and the regulator holds the operator's set pressure through each pressing cycle.
Real choices in this family: step the size and port (200/300/400/600; here 400 with a PT1/2 port) against the flow your line needs; pick the drain - automatic on this unit, with differential-pressure (default) and manual also available; choose the 40 um standard element or the 5 um (W) option; select thread PT as the standard with G (BSPP) and NPT orderable; and specify a gauge if you want a visual pressure readout, since none is fitted here (MPa, psi or bar scales are orderable). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Share your line pressure, set pressure and demand and we will confirm the sizing from the datasheet on request.
The N in GFC40015AN means no gauge is fitted. Units with a regulator can take an embedded square gauge or an optional external round gauge, with MPa, psi or bar scales orderable - tell us the scale you want and we will confirm the option on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.