AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015C1K)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015C1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$111.74 $118.20Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015C1K)

The AirTAC GFC series combines a filter-regulator and a lubricator into one two-unit F.R.L. set for filtration, pressure regulation and oil-mist lubrication of compressed air. This GFC40015C1K is built in size 400 with PT 1/2 in ports (PT is the standard thread), a differential-pressure drain on the filter bowl, the standard 40 um filter element, an external round gauge with MPa scale, and a reverse/check valve fitted as part of the configuration. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator covers 0.15-0.9 MPa (20-130 psi), and the PC (polycarbonate) bowls suit -5 to 70 C (non-freezing) service.

This is a genuine AirTAC part in the G series range (sizes 200/300/400/600, ports from 1/8 to 1 inch), with catalogue options including automatic or manual drains, 5 um elements, square embedded gauges, and G (BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so share your circuit details and we will confirm the datasheet and sizing figures on request.

AirTAC GFC400-15 Combination Unit (GFC40015C1K) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015C1K)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015C1K)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015C1K) Is Used

tune

Pneumatic press setting

Supplying small pneumatic presses and marking heads, where the external round MPa gauge supports repeatable pressure setting and the fitted reverse/check valve matches the specified circuit.

handyman

Maintenance workshop benches

Feeding air tools at a maintenance bench, with filter, regulator and lubricator in one set, the MPa gauge for setting, and the differential-pressure drain clearing collected water.

engineering

Pneumatic test rig supply

Conditioning supply on pneumatic test benches, where the check-valve configuration and MPa-scaled round gauge suit repeat test setups and lubrication protects the rig's cylinders.

Is the AirTAC GFC400-15 Combination Unit (GFC40015C1K) the Right Set?

Size 400 with 1/2 in ports is the middle step of the G series; move to 600 or down to 300/200 as port and demand require. The K suffix here means a reverse/check valve is fitted; order the non-K code when your circuit does not specify one. The blank drain position gives the differential-pressure type, which clears condensate as pressure drop builds; automatic and manual drains are alternatives. The 40 um element is the standard grade, with 5 um available via the W suffix. C1 specifies the round external gauge on the MPa scale; square embedded gauges and psi/bar scales are also offered. PT thread is standard; G (BSPP) and NPT are order options.

Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015C1K) FAQ

AirTAC publishes G series flow as curves rather than a single rated figure, so no flow number is stated here. Give us your supply pressure, downstream demand and allowable pressure drop, and we will confirm the datasheet curves and sizing on request before you order.

Only the trailing K: the C1K has a reverse/check valve fitted, while the C1 does not. Size 400, PT 1/2 in ports, differential-pressure drain, 40 um element and the round MPa gauge are identical in both codes.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015C1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.