The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015C3W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC40015C3W is an AirTAC G-series two-unit air treatment set: a filter regulator and a lubricator paired as one 2-piece combination. This size 400 unit has 1/2 in PT ports, the 5 um filter element (code W) instead of the 40 um standard, and a differential-pressure drain on the filter bowl. The regulator adjusts from 0.15-0.9 MPa (20-130 psi) and the external round gauge reads in bar. Bowls on the 400 size are PC (polycarbonate); maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C, non-freezing. The medium is compressed air only.
This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 to 1 in, plus catalogue options for drain type (differential-pressure, automatic or manual), filter grade, gauge style and scale, and G (BSPP) or NPT threads. Flow for the series is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015C3W) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Serves the atomizing and blow-off points on an automotive trim paint line, where the 5 um element supports cleaner air ahead of the spray application valves.
Prepares the supply for pick-and-place head cylinders on an electronics assembly cell; the 5 um element suits the small valve packages downstream.
Feeds gripper and door actuators on laboratory automation equipment, with the bar-scaled round gauge giving a local setpoint reading at the bench.
Size 400 with PT1/2 ports sits in the upper half of the G range (sizes 200 to 600, ports 1/8 to 1 in); match the port step to your line's piping and demand. This unit carries the W code, selecting the finer 5 um element over the 40 um standard - useful ahead of sensitive valve packages. Drain type on the filter bowl is differential-pressure here; automatic (A) and manual (M) versions exist. Gauge: the external round gauge with bar scale is fitted; the embedded square gauge in MPa, psi or bar scales is also available. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so no one number is quoted here. Tell us your working pressure and demand and we will confirm the flow and datasheet figures for this model on request before you order.
The W code selects the 5 um element for finer particulate removal ahead of sensitive valves and actuators; the code without W is the 40 um standard. Drain type, gauge and thread are chosen independently of the filter grade.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.