AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015F1K)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015F1K) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$111.74 $118.20Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015F1K)

GFC40015F1K is an AirTAC G-series two-unit air treatment set: a filter regulator and a lubricator paired as one 2-piece combination. This size 400 unit has 1/2 in PT ports, a 40 um filter element and a differential-pressure drain on the filter bowl. The regulator adjusts from 0.15-0.9 MPa (20-130 psi) and the embedded square gauge reads in MPa. A fitted reverse (check) valve holds downstream pressure when the upstream supply is shut off. Bowls on the 400 size are PC (polycarbonate); maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C, non-freezing. The medium is compressed air only.

This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 to 1 in, plus catalogue options for drain type (differential-pressure, automatic or manual), 40 um or 5 um filtration, gauge style and scale, and G (BSPP) or NPT threads. Flow for the series is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.

AirTAC GFC400-15 Combination Unit (GFC40015F1K) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015F1K)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015F1K)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015F1K) Is Used

local_shipping

Warehouse dock levellers

Runs the air cylinders on dock leveller platforms; the check valve holds the platform position if the shop air supply drops during a loading cycle.

tune

Welding cell clamping air

Feeds the fixture clamps and tool-changer cylinders in a robotic welding cell, with the MPa square gauge for setpoint adjustment at the cell.

valve

Process skid valve actuators

Supplies pilot air to the pneumatic valve actuators on a process skid; the check valve keeps the pilot line pressurised through upstream supply switching.

Is the AirTAC GFC400-15 Combination Unit (GFC40015F1K) the Right Set?

Size 400 with PT1/2 ports sits in the upper half of the G range (sizes 200 to 600, ports 1/8 to 1 in); move up or down a size to match your piping and demand. The K code fits a reverse (check) valve, which holds downstream pressure on supply loss - order without K if you do not need it. Drain type on the filter bowl is differential-pressure here; automatic (A) and manual (M) versions exist. Filtration is 40 um standard, with 5 um available under the W code. Gauge: this unit is coded F1, the embedded square gauge in MPa; C codes select the external round gauge in MPa, psi or bar. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015F1K) FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no number is stated here. Give us your line pressure and demand and we will confirm the flow and datasheet figures for this model on request before you order.

GFC combines the filter regulator and lubricator as a two-piece set; GC is the three-piece filter, regulator and lubricator. Both filter, regulate and lubricate, so the choice is mainly mounting layout and whether you want the three functions as separate serviceable pieces.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015F1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015F1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.