AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015F1W)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015F1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$100.39 $106.57Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015F1W)

GFC40015F1W is an AirTAC G-series two-unit air-treatment set for compressed air: a filter regulator and a lubricator combined as one 2-piece assembly. In this size 400 unit the PT1/2 ports take a half-inch line, the W code fits the finer 5 um filtration element, and the polycarbonate filter bowl carries the standard differential-pressure drain that bleeds condensate as flow resumes. The regulator has an embedded square gauge reading in MPa and adjusts between 0.15 and 0.9 MPa (20-130 psi); the lubricator feeds an oil mist to downstream equipment. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part supplied by a US distributor. The G series spans sizes 200, 300, 400 and 600 with a choice of ports, drain types (differential-pressure, automatic or manual), 5 um or 40 um filtration, gauge scales, and thread options with PT as the standard (G and NPT are catalogue options to order). Flow is published as curves rather than one rated number, so we confirm sizing and datasheet figures on request.

AirTAC GFC400-15 Combination Unit (GFC40015F1W) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015F1W)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015F1W)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015F1W) Is Used

precision_manufacturing

CNC machining cells

Feeds tool-changer and spindle-clamp valves on a machining centre with 5 um filtered, regulated air, while the lubricator mists the clamp and ejector cylinders.

air

Paint booth spray equipment

Supplies finer 5 um air to refinish spray guns and booth actuators, with the regulator setting gun supply pressure and the lubricator serving downstream air cylinders.

conveyor_belt

Packaging carton sealers

Conditions the air driving carton-closing and taping heads on a packaging line, keeping contaminants out of seal cylinders and keeping sliding surfaces oiled.

Is the AirTAC GFC400-15 Combination Unit (GFC40015F1W) the Right Set?

Size 400 with PT1/2 ports is the mid-large step of the G series; step up to 600 for larger ports and more flow, or down to 300 when demand is lighter. This unit uses the differential-pressure drain; specify the A code for an automatic drain or M for a manual drain if your line idles frequently. The W code selects the 5 um element for finer protection of valves and instruments, versus the standard 40 um grade. The F1 square gauge reads MPa, with other scales available. Thread is PT as standard; G (BSPP) and NPT versions are catalogue options to order. AirTAC publishes flow as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015F1W) FAQ

AirTAC publishes flow for the G series as performance curves rather than one rated number, so we do not quote a single figure here. Send us your working pressure and air demand and we will confirm sizing from the datasheet on request.

The W in the code selects the optional 5 um element instead of the standard 40 um grade. Choose 5 um where downstream valves, cylinders or instruments need finer protection; 40 um suits general pre-filtration. Both grades work with the same bowls and drain arrangements.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015F1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015F1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.