The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015LC1) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC40015LC1 is a genuine AirTAC G-series two-unit air-treatment set: a filter-regulator and a lubricator supplied as one matched pair, so a single order covers water and particulate removal, pressure regulation and oil-mist lubrication of a compressed-air line. This size 400 unit is threaded PT1/2 (1/2 in), carries the standard 40 um filter element and a differential-pressure drain, and is built on the low-pressure (L) regulator type. A round external pressure gauge on the MPa scale is included. Both bowls on this 400 size are PC (polycarbonate). Max working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C (non-freezing); the medium is compressed air only.
This is a genuine AirTAC part sold through our US distribution. The GFC two-unit series spans sizes 200, 300, 400 and 600, with drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um (W) filtration, gauge scales in MPa, psi or bar, and G (BSPP) or NPT thread options. AirTAC publishes flow for these units as curves rather than a single rated figure, so we confirm the flow and datasheet figures for your application on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015LC1) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Conditions the supply feeding tool-clamp and pallet-changer cylinders on a CNC machining centre: water and chips-scale particulate removed, pressure held steady at the set point, and oil mist carried to the actuators.
Serves as the treatment point ahead of directional control valves on a carton-forming and sealing line, keeping condensate and 40 um-scale dirt out of the valve stack while the regulator holds line pressure for consistent jaw action.
Fitted at the air drop serving impact wrenches and nutrunners on an assembly bench, where the lubricator keeps tool motors oiled and the regulator caps supply pressure to the rated working pressure of the tools.
Size 400 with PT1/2 ports sits toward the larger end of the G-series range; step down to 300 or up to 600 when your machine's port or pipe size calls for it. Drain options are the differential-pressure drain fitted here, automatic (A) for unattended condensate removal, or manual (M). The 40 um element suits general machine air; choose the W option for 5 um where downstream valves and cylinders are more sensitive. Gauge choices are the round external gauge in MPa fitted here, the embedded square gauge, psi or bar scales, or no gauge. This code is the low-pressure (L) regulator type; its setting range is specific to that type and we confirm the exact figures on request. Thread is PT as standard, with G (BSPP) or NPT available to order. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for the G series as capacity curves rather than one rated figure, so we do not quote a single number here. Tell us your working pressure and air demand and we will confirm the flow and datasheet figures for this exact unit on request.
The L selects AirTAC's low-pressure regulator type in place of the standard type, and that type carries its own setting range, which we confirm on request. Everything else decodes the same: PT1/2 ports, 40 um element, differential-pressure drain and the included MPa round gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.