verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015MLC1W)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015MLC1W) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$100.39 $106.57Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015MLC1W)

GFC40015MLC1W is a genuine AirTAC G-series two-unit set: a filter regulator and a lubricator supplied as two matched 1/2 in. PT-threaded units. The W code fits the 5 um filter element instead of the standard 40 um grade, for finer removal of water carry-over and particulate, with a manual-drain bowl for emptying on demand. The regulator stage is the L low-pressure type for circuits set below the standard range - we confirm its exact adjustment window from the datasheet on request - and pressure is read on the external round gauge scaled in MPa. The lubricator meters oil mist downstream. Maximum inlet pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G series runs in 200, 300, 400 and 600 sizes with PT (standard), G(BSPP) and NPT threads, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and square embedded or round external gauges in MPa, psi or bar scales. Size 400 units use polycarbonate bowls. Flow is published as curves rather than a single rated figure, so we confirm datasheet and sizing figures on request.

AirTAC GFC400-15 Combination Unit (GFC40015MLC1W) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015MLC1W)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015MLC1W)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015MLC1W) Is Used

valve

Instrument-air leg on a process skid

Supplying fine-filtered, low-pressure air to positioners and pilot valves on a chemical dosing skid, where 40 um particles would score the pilot seats.

view_module

Electronics pick-and-place modules

Feeding the vacuum ejectors and Z-axis cylinders of SMT pick-and-place modules with 5 um-filtered, gently regulated air to protect nozzle seals and board quality.

air

Air-bearing and low-pressure jig clamps

Running air-jig flotation pads and low-pressure clamp circuits on a machining fixture table, where coarse dirt would block the small flotation orifices.

Is the AirTAC GFC400-15 Combination Unit (GFC40015MLC1W) the Right Set?

This is the fine-filtration build of the 400-size, 1/2 in. low-pressure set: W selects the 5 um element over the 40 um standard - useful ahead of sensitive valves and instruments, at the cost of a more frequent element check. The L code marks the low-pressure regulator; we confirm its adjustment range on request. The M code sets a manual drain (blank is differential-pressure, A is automatic), and the gauge is the external round type in MPa, with the embedded square gauge and psi or bar scales as alternatives. PT is the standard thread, with G(BSPP) and NPT available to order, and a bracket option for mounting. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015MLC1W) FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no one number is quoted here. Note also that a 5 um element holds back more dirt than the 40 um standard and should be checked more often. Send your pressure and demand figures and we will confirm sizing from the datasheet on request.

W selects the 5 um filter element in place of the 40 um standard grade. The rest of the code reads as before: L is the low-pressure regulator type, M is the manual drain (blank is differential-pressure, A is automatic), and C1 is the external round gauge in MPa. We confirm the low-pressure adjustment range on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015MLC1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015MLC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.