AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015MNK)

The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015MNK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$106.09 $112.41Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFC400-15 Combination Unit (GFC40015MNK)

The AirTAC GFC40015MNK is a two-unit air-treatment set: a filter regulator and a separate lubricator in one 400-size package, providing filtration, regulation and lubrication in one installation. This variant adds the K option - a reverse (check) valve fitted in the regulator section; for full check-valve behaviour and limits, confirm the detail on the datasheet. The set is PT1/2 ported with PT threads as standard, the filter bowl has a manual drain, and the element is the standard 40 um grade. The regulator is the standard type and, with the manual-drain configuration, adjusts over 0.05-0.9 MPa (7-130 psi); maximum working pressure is 1.0 MPa (145 psi). No gauge is fitted.

This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with optional G (BSPP) and NPT thread variants, automatic or differential-pressure drains, a 5 um (W) element option and gauge choices on regulator-equipped units. The 400-size bowls on the filter and lubricator are PC (polycarbonate). Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

AirTAC GFC400-15 Combination Unit (GFC40015MNK) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015MNK)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015MNK)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015MNK) Is Used

valve

Valve-actuation skid air supply

Use the GFC40015MNK on a skid that strokes automated process valves, so the check-valve option and 40 um filtration protect the positioner and solenoid valves on one regulated, lubricated 1/2 inch line.

engineering

Press-shop pneumatic workholding

Fit the set ahead of clamps and swing cylinders on a machining cell's workholding circuit, where the check valve helps the circuit keep its configuration and the manual drain is blown down at shift start.

local_shipping

Trailer and dock-air treatment point

Install the two-unit set at a dock or trailer-testing station fed from the workshop compressor, giving filtered, regulated, lubricated air to test couplings and actuated landing-gear or door rigs.

Is the AirTAC GFC400-15 Combination Unit (GFC40015MNK) the Right Set?

Choose this K variant over the plain GFC40015MN when your circuit needs the reverse (check) valve option fitted at the regulator; otherwise the decode is identical - 400 size, PT1/2 ports, manual drain and 40 um element. Manual drain suits attended plants where bowls are blown down on a routine; pick automatic or differential-pressure drain codes for unattended lines. If you need finer pre-filtration, the 5 um (W) element is the alternative grade. No gauge is included in this code, so consider adding a gauge option when ordering, and switch to the G or T thread suffix if your pipework is BSPP or NPT rather than PT. Flow is published as curves, not a single rating, so ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015MNK) FAQ

No single rated flow is published for the 400-size G series - AirTAC provides characteristic curves instead. Send us your application pressure and air demand and we will confirm the right size from the datasheet on request before you order.

Only the K option: the MNK has a reverse (check) valve fitted in the regulator section, while the plain MN does not. Everything else decodes the same - 400 size, PT1/2 ports, PT thread, manual drain, 40 um element, standard regulator and no gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015MNK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC40015MNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.