The AirTAC AirTAC GFC400-15 Combination Unit (GFC40015NK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC40015NK is AirTAC's G-series two-unit air preparation set for 1/2 in PT threaded lines, combining a filter-regulator and a lubricator so one assembly filters, regulates and lubricates compressed air. The K code adds a reverse (check) valve, which holds downstream pressure if the upstream supply drops. This version uses the standard 40 um filter element, a differential-pressure drain, and carries no gauge (N code).
This is a genuine AirTAC part in the 400 size of the G series, which also spans 200, 300 and 600 sizes with ports from 1/8 to 1 in. Options include automatic or manual drains, a 5 um element (W code), gauge variants, and G (BSPP) or NPT threads. We confirm flow and datasheet figures on request.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015NK) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Supplies regulated, lubricated air to pneumatic clamp cylinders on a weld fixture, with the check valve helping hold the clamped position if the main supply dips mid-cycle.
Prepares air for the vacuum and clamp grippers of a palletizing cell, filtering plant air, holding a stable set pressure and feeding a light oil mist to the directional valves.
Conditions the branch feeding solenoid valves and air cylinders on a stamping press's secondary operations, keeping water and scale out of the valve stack.
Size the unit by stepping between 200, 300, 400 and 600 to match port and air demand; the 400 size carries the 1/2 in PT port shown here. Pick the drain type: differential-pressure (this model), automatic (A) or manual (M). The 40 um element covers general plant air; the W variant gives 5 um filtration. Keep the K code if you want the check valve to hold the regulated downstream pressure during supply dips, and choose a gauge variant in place of the N no-gauge code if you need a reading. Threads come as PT (standard), G (BSPP) or NPT. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for this series as performance curves rather than a single rated figure, so no number is quoted here. Tell us your inlet pressure and required air consumption and we will confirm the flow from the datasheet on request.
The K code means a reverse (check) valve is fitted, so air flows out to the line but is held from flowing back if the upstream supply fails or dips. The base GFC40015N without the K does not include this valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.