verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC400C10C1

The AirTAC Airtac GFC Combination Unit GFC400C10C1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$116.28 $122.85Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC400C10C1

The GFC400C10C1 is a genuine AirTAC G-series two-unit air-treatment set: a filter regulator and a lubricator supplied as a matched pair, so one purchase covers filtration, pressure regulation and oil-mist lubrication for downstream cylinders, valves and air tools. This configuration is size 400 with PT3/8 ports (PT is the standard thread; G and NPT are catalogue options), uses 40 um standard filtration, differential-pressure drain bowls in polycarbonate, and an external round gauge on an MPa scale. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjustment range with differential-pressure drain is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C, non-freezing. Medium: compressed air only.

The G series is offered in sizes 200, 300, 400 and 600, with automatic or manual drain options, a 5 um fine-filtration element (W suffix), embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads to order. Flow for these units is published as curves rather than a single rated figure, so we confirm flow and datasheet details for your application on request.

Airtac GFC Combination Unit GFC400C10C1 Technical Specifications

ModelAirtac GFC Combination Unit GFC400C10C1
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC400C10C1

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC400C10C1 Is Used

precision_manufacturing

Stamping press air circuit

Feeding filtered, regulated and lubricated air to the clutch and cylinder circuit of a mechanical punch press on a metal stamping shop floor.

conveyor_belt

Carton sealing line

Conditioning supply air for the cylinder-driven tuck, fold and taping heads along a corrugated carton sealing and packing line.

bolt

Impact wrench stations

Supplying regulated, oil-misted air to impact wrench and nutrunning stations at an automotive assembly trim line.

Is the Airtac GFC Combination Unit GFC400C10C1 the Right Set?

Start with size: 400 with PT3/8 sits in the mid-range of the G series, which steps through 200, 300, 400 and 600 with growing ports and flow capacity; match the size to your pipe and demand. Drain type is your next choice: the differential-pressure drain here is the standard, automatic drain suits unattended installations, and manual drain is for points you bleed off regularly. Filtration is 40 um as standard; add the W suffix for a 5 um element when finer protection is needed. The C1 suffix brings an external round gauge in MPa; psi or bar scales and an embedded square gauge are alternatives. Thread is PT as standard, with G (BSPP) and NPT as order options. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm sizing against your actual flow demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC400C10C1 FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Send us your flow demand and application and we will confirm sizing against the datasheet curves on request before you order.

The 40 um element on this model is the standard grade and suits general plant air protecting cylinders, valves and tools. The W suffix (GFC400C10C1W) gives a 5 um element for finer protection such as precision valve trains or instrument air. Drain type, gauge scale and thread can also be re-specified when you order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC400C10C1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC400C10C1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.