AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC400C10MNW

The AirTAC Airtac GFC Combination Unit GFC400C10MNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.63 $117.06Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC400C10MNW

The AirTAC GFC series is a two-unit F.R.L. set: a filter-regulator plus a lubricator, covering water and particulate removal, pressure regulation and oil-mist lubrication from one order on a compressed-air line. This set is size 400 with 3/8 in. PT ports (PT is the standard thread; G/BSPP and NPT are catalogue options), the 5 um filter element (W code) instead of the 40 um standard, and a manual drain on the filter bowl; the trailing N means it is ordered without a pressure gauge. With the manual drain the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), working pressure is up to 1.0 MPa (145 psi), and the PC (polycarbonate) bowls serve the -5 to 70 C, non-freezing range.

This is a genuine AirTAC part. The G series runs in sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., and family options include automatic and differential-pressure drains, the 40 um standard element, embedded square or external round gauges (MPa, psi or bar scales), G/NPT threads, brackets and a reverse (check) valve. Flow is published as curves rather than a single rated figure, so send us your conditions and we will confirm sizing and datasheet figures on request.

Airtac GFC Combination Unit GFC400C10MNW Technical Specifications

ModelAirtac GFC Combination Unit GFC400C10MNW
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC400C10MNW

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC400C10MNW Is Used

science

Laboratory test rig supply

The 5 um element suits bench-scale test rigs and instrument panels where a finer particulate step ahead of downstream regulators and instrumentation is wanted.

view_module

Modular assembly stations

Per-station air prep on a modular assembly line, with the 5 um element adding a finer step over the 40 um standard for more sensitive actuators and circuits.

air

Bottling line sorting gates

Runs sorting gates and diverters on a bottling line from one filtered, regulated and lubricated supply point built on 3/8 in. ports.

Is the Airtac GFC Combination Unit GFC400C10MNW the Right Set?

Size and port step against flow is the first decision: the G series runs 200/300/400/600 with ports from 1/8 in. to 1 in., and because flow is published as curves rather than one rated number, ask us to confirm sizing before you order. Drain: the M in this code is the manual drain, against the differential-pressure default and the automatic option; a manual drain also lets the regulator start adjusting at 0.05 MPa (7 psi). The W selects the 5 um element over the 40 um standard - pick it where downstream equipment wants a finer step. The N suffix means no gauge is fitted - embedded square or external round gauges in MPa, psi or bar scales are catalogue options. Thread is PT as standard, with G (BSPP) and NPT specified at order, and bracket options are available.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC400C10MNW FAQ

AirTAC publishes flow for the G series as performance curves, not as a single rated figure, so we do not quote one number here. Send us your working pressure and required flow and we will confirm sizing against the datasheet curves on request.

40 um is the standard element for general plant air; the W suffix specifies the 5 um element for a finer step where downstream equipment is more sensitive. The grade applies to the filter stage only - the lubricator is unchanged. Both are catalogue options on GFC400, and we can confirm the current datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC400C10MNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC400C10MNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.