verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC400C15AN

The AirTAC Airtac GFC Combination Unit GFC400C15AN is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$121.07 $127.76Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC400C15AN

The AirTAC GFC400C15AN is a two-unit air preparation set from the G series: a filter-regulator and a separate lubricator, size 400, piped PT1/2 (1/2 inch), for compressed air only. In service the filter-regulator bowl removes water and particulate through the standard 40 um element, the regulator holds your set downstream pressure (0.15 to 0.9 MPa / 20-130 psi adjustment on this automatic-drain version), and the lubricator meters an oil mist into the clean air for downstream cylinders and tools. The bowl drains automatically, no pressure gauge is fitted (code N), and maximum working pressure is 1.0 MPa (145 psi) over a -5 to 70 C, non-freezing range. Bowls in the 400 size are polycarbonate.

This is a genuine AirTAC part, one configuration of a family that runs from size 200 to size 600 with ports from 1/8 to 1 inch. Catalogue options include the 5 um W element, manual or differential-pressure drains, embedded square or external round gauges in MPa, psi or bar scales, reverse (check) valve versions, a low-pressure type, and G (BSPP) or NPT threads in place of the PT standard. AirTAC publishes flow as curves rather than a single rating, so ask us and we will confirm the datasheet and figures for this exact model on request.

Airtac GFC Combination Unit GFC400C15AN Technical Specifications

ModelAirtac GFC Combination Unit GFC400C15AN
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC400C15AN

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC400C15AN Is Used

precision_manufacturing

Robotic palletizer gripper circuit

Filtered, regulated and lubricated air for the gripper cylinders and vacuum generator on a palletizing robot's end-of-arm tooling, fed from a 1/2 inch drop with the setpoint set once at the cell.

conveyor_belt

Bottling line diverters

Supplies the stopper and diverter cylinders along a bottling hall conveyor; the automatic drain clears condensate at an unattended drop without a daily manual drain routine.

settings_input_component

Case erector valve stack

Prepares air for the solenoid valve stack driving the clamp and flap-fold cylinders of a corrugated case erector, with the 40 um element protecting the valve seats.

Is the Airtac GFC Combination Unit GFC400C15AN the Right Set?

Match the 400 size and its 1/2 inch PT ports to the flow your line actually needs: stepping to size 300 or 600 changes the port and the capacity, and because AirTAC publishes flow as curves rather than one rated number, send us your application and we will confirm sizing before you order. Then set the remaining decodable choices: drain type (automatic here, with manual and differential-pressure as catalogue alternatives), element grade (40 um standard here, 5 um with the W code), gauge (none fitted on this N version; embedded square or external round gauges in MPa, psi or bar scales are options), and thread (PT standard, with G and NPT as orderable specifications). Low-pressure type and reverse-valve versions also exist in this family.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC400C15AN FAQ

AirTAC publishes G series flow as performance curves rather than a single rated figure, so no rated flow number is quoted here. Send us your line pressure and air demand and we will confirm the flow data and full datasheet for this exact model on request.

N means this set is supplied without a gauge. G series units with a regulator accept an embedded square gauge, and an external round gauge is optional, in MPa, psi or bar scales; order the catalogue code with the gauge option you want.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC400C15AN

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC400C15AN and will confirm price, stock and lead time — usually within 7-8 hours.