verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC400C15N

The AirTAC Airtac GFC Combination Unit GFC400C15N is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.63 $117.06Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC400C15N

GFC400C15N is a genuine AirTAC G-series two-unit set combining a filter-regulator with a lubricator, so filtration, pressure regulation and oil-mist lubrication of compressed air come from a single order. This size 400 configuration is ported 1/2 in with PT thread as standard and carries the default 40 um filter grade, which suits general plant air feeding cylinders, directional valves and blow-off points. The bowls use the default differential-pressure drain, the regulator adjusts from 0.15-0.9 MPa (20-130 psi), and neither a gauge nor a check valve is fitted. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C.

The G-series two-unit family spans sizes 200, 300, 400 and 600, with differential-pressure, automatic or manual draining, 40 um standard or 5 um fine filtration, gauge options, check-valve variants, and G (BSPP) or NPT threads as catalogue alternatives to the standard PT. On this size both bowls are polycarbonate. Flow for the series is published as curves rather than a single rated figure, so we confirm datasheet and flow figures for your application on request.

Airtac GFC Combination Unit GFC400C15N Technical Specifications

ModelAirtac GFC Combination Unit GFC400C15N
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC400C15N

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC400C15N Is Used

conveyor_belt

Conveyor blow-off station

Feeds air-nozzle blow-off points along a packaging conveyor, where 40 um general-purpose air is adequate and the lubricator keeps the drive cylinders running smoothly through each shift.

factory

Plant drop legs

Installed on a main air drop serving a production bay, filtering and regulating the supply for a mix of cylinders, clamps and hand tools, with the lubricator dosing whatever air tools hang on the line.

build

Pneumatic clamping fixture

Prepares air for swing clamps and support cylinders on a machining fixture, holding a stable regulated pressure for repeatable clamping without needing a gauge at the set.

Is the Airtac GFC Combination Unit GFC400C15N the Right Set?

This is the straightforward configuration of the set: size 400 with a 1/2 in PT port, default 40 um filtration and the default differential-pressure drain. If your flow demand is larger or smaller, step up to GFC600 or down to GFC300 for a different port size. Choose the 5 um (W) variant if the same air line feeds spraying, instrumentation or sensitive valves; stay with 40 um for general actuation. The regulator covers 0.15-0.9 MPa (20-130 psi) on this drain version, and no gauge is fitted, so add one if operators need to read the set pressure.

Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC400C15N FAQ

The G-series flow data is published as curves, not as a single rated number, so we do not state one figure here. This size 400 unit with its 1/2 in port serves mid-to-high demand circuits in the family. Tell us your required flow and we will confirm the datasheet curves and figures for this exact model on request.

Differential-pressure draining is the default on this series: condensate is discharged in response to a pressure differential, with no daily visit needed. The alternative automatic drain expels condensate continuously, while the manual drain is emptied by hand and widens the regulator range to 0.05-0.9 MPa (7-130 psi) instead of 0.15-0.9 MPa (20-130 psi). We can quote any of the three drain versions of this model.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC400C15N

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC400C15N and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.