The AirTAC AirTAC GFC600-20 Combination Unit (GFC60020MNW) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air-preparation set: a filter regulator paired with a lubricator, covering filtration, pressure regulation and oil-mist lubrication on one line. This code is the 600 size with a 3/4 in PT port, a manual-drain filter bowl and a 5 um element, ordered without a gauge (the N in the code). The 600-size bowls are aluminium alloy. Maximum working pressure is 1.0 MPa (145 psi), and with the manual drain the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi).
It is a genuine AirTAC part across the G-series range of 200, 300, 400 and 600 sizes, with differential-pressure, automatic or manual drainage, 40 um standard or 5 um fine filtration, and PT, G (BSPP) or NPT threads. Operating temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.
| Model | AirTAC GFC600-20 Combination Unit (GFC60020MNW) |
|---|---|
| Series | GFC600 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC600 | G-series two-unit set, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR600-20 filter regulator and GL600-20 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC600 · PT3/4" · 5 µm |
|---|---|
| One size down | GFC400 |
| Three-unit equivalent | GC600-20 |
| Build order | Filter regulator first, lubricator last |
Serves the overhead air drops in a truck or trailer maintenance garage, giving technicians filtered, regulated, lubricated air for tools and jacks at a set pressure.
Prepares the air at multi-operator assembly benches where nutrunners and air cylinders share one 3/4 in supply, with the 5 um element protecting the tools.
Conditions the supply on a pneumatics test rig where a 5 um element and stable regulated pressure matter, and where the rig carries its own instrumentation instead of a unit gauge.
Choose the size to match your line: 200, 300, 400 and 600 with ports from 1/8 in up to 1 in; this is the 600 size on 3/4 in PT. Drainage on the filter bowl is manual here (M), which widens the regulator window to 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drains are the other codes. The element is the 5 um fine grade (W); 40 um is standard. Gauge choice is made in the code: N means no gauge, while C and F codes select round or square gauges with MPa, psi or bar scales. PT is the standard thread with G (BSPP) and NPT as order options, and a bracket can be specified.
Flow is published as curves rather than a single rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GFC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR600-20 filter regulator on its own.
We confirm flow from the datasheet on request, because AirTAC publishes flow for this series as curves rather than a single rated figure. Give us your line pressure and the air your equipment consumes, and we will check this 600-size, 3/4 in set against the application before you order.
No - the N in the code means the set is supplied without a gauge. Gauge selection is made in the code when ordering: N for none, or C and F codes for round or square gauges with MPa, psi or bar scales. Everything else decodes as the 600 size, 3/4 in PT port, manual drain and 5 um element.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.