The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006F3) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR20006F3 is an AirTAC G-series filter regulator: filtration and pressure regulation in a single body. This size 200 configuration has a PT1/8" port, the standard 40 um filter element, the standard differential-pressure drain on its polycarbonate bowl, and an embedded square gauge reading outlet pressure in bar. Maximum inlet pressure is 1.0 MPa (145 psi), the regulated range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi), and operating temperature is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8" to 1", a choice of manual, automatic or differential-pressure drains, 40 um or 5 um elements, MPa/psi/bar gauge scales, and G (BSPP) or NPT threads as catalogue options; a mounting bracket is included as standard. Flow is published as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006F3) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
General air preparation at a maintenance workshop outlet, filtering standard shop air to 40 um and holding a stable regulated pressure for hand-held pneumatic tools and test rigs.
Feeding screwdrivers, clamps and small actuators at an assembly workstation, with the bar-scale gauge matching the workshop's pressure gauges so setpoints are read consistently.
Conditioning the air entering a machine's pneumatic control section, giving the panel builder a compact filter regulator at the 1/8" entry point with local pressure indication in bar.
Size 200 suits the smallest port requirement in the GFR range; step to 300, 400 or 600 as port size and flow demand grow. The standard 40 um element fitted here covers general-purpose air preparation; specify the W variant for the finer 5 um grade. Drain choices are the differential-pressure drain fitted here, an automatic drain (A) or a manual drain (M) - the regulated range starts at 0.05 MPa with a manual drain instead of 0.15 MPa. The embedded square gauge reads in bar (scale 3); MPa and psi scales are orderable. Thread is PT as the standard, with G (BSPP) and NPT as catalogue options, and a mounting bracket is included. Because flow is published as curves, not a single rating, ask us to confirm sizing against your flow requirement before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC does not publish a single rated flow number for this series; flow is given as characteristic curves. Tell us your supply pressure and the flow your circuit requires and we will confirm the datasheet curve figures for this exact model on request.
The F3 code specifies the embedded square gauge with a bar scale. MPa (1) and psi (2) scale variants are available in the same family, so if your plant reads in another unit, ask us for the matching GFR200 code before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.