The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006LF1) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR20006LF1 is an AirTAC G-series filter regulator: filtration and pressure regulation combined in one body. This 200-size unit carries a PT1/8 port, a polycarbonate bowl with a differential-pressure drain, a standard 40 um filter element and the low-pressure (L) type regulator, whose adjustment range is reduced compared with the standard type. An embedded square gauge with MPa scale and a mounting bracket are included.
This is a genuine AirTAC part from the GFR200-300-400-600 series. Other drain types, a 5 um element, G or NPT thread options, psi and bar gauge scales and a check valve are all catalogue variants - ask for any of them. Flow for the G-series is published as curves rather than a single rated figure, so we confirm datasheet numbers for you on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006LF1) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Sits ahead of a paint gun on a coating booth, filtering water from shop air and stepping the pressure down to the gentle setting fine finishing work needs.
Feeds light pick-and-place grippers on an assembly cell, where a 1/8" filter regulator keeps small cylinders moving on a clean, steady low-pressure supply.
Conditions air for lab and QC rigs - the polycarbonate bowl drops out condensate while the regulator holds a low, repeatable setting for sensitive fixtures.
Size steps in 200/300/400/600 with ports from 1/8" to 1" let you match the unit to your line - step up a size when the circuit needs more flow. Drain choices are differential-pressure (the default here), automatic (A) or manual (M); the element is 40 um standard or 5 um (W); gauge scales are MPa, psi or bar; thread is PT as standard with G and NPT orderable as catalogue options. Because this is the low-pressure (L) type, its adjustment range is smaller than the standard type - we confirm the exact figures on request.
Note that rated flow is published as curves, not a single number, so please ask us to check sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure and flow target and we will confirm from the datasheet whether the 200 size with PT1/8 ports is correctly sized, at no obligation.
The L suffix makes this the low-pressure regulator variant of the GFR20006LF1, with a reduced adjustment range compared with the standard type. The differential-pressure drain, 40 um element, square MPa gauge and bracket are otherwise the defaults. We confirm the exact adjustment range from the datasheet on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.