The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006MF1) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines an air filter and a pressure regulator in one body: air passes through a drain bowl and filter element, then a regulating valve sets the downstream pressure. This GFR20006MF1 is the 200 size with a PT1/8 (1/8 in) port, a manual-drain polycarbonate bowl, a 40 um standard element and an embedded square gauge with MPa scale. With manual drain the regulator adjusts 0.05-0.9 MPa (7-130 psi); maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, drain options, 5 um (W) elements, gauge scales in MPa, psi or bar, and G or NPT threads as catalogue options. Flow for filter regulators is published as curves rather than a single rated figure, so we confirm datasheet numbers for your application on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006MF1) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeds filtered, regulated air to the pneumatic clamps on a carton-sealing line so cylinder pressure stays where the line was set, with condensate drained at the bowl.
Supplies a set pressure to the blow-off nozzles on an assembly bench, with water and particulate removed upstream so parts leave the station dry and clean.
Conditions the shop-air supply to a compact CNC's pneumatic tool clamp, with the MPa gauge giving the operator a local downstream pressure readout.
The 200 size with 1/8 in port suits compact branch lines; step up to 300, 400 or 600 for larger ports and higher flow capacity. Manual drain suits points where an operator walks the line; automatic or differential-pressure drains are available where bowls are not reached regularly. The 40 um element is standard; specify W for 5 um. Choose MPa, psi or bar gauge scale, PT (standard) or G/NPT thread, and a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes filter-regulator flow as curves, not a single rated figure, so no rated number is quoted here. Ask us and we will confirm the datasheet flow curve and sizing for your 1/8 in application before you order.
Manual drain (M) needs someone to open the bowl during checks, but it allows the widest regulating range of 0.05-0.9 MPa (7-130 psi). Choose automatic or differential-pressure drain where the bowl cannot be reached regularly; those variants regulate 0.15-0.9 MPa (20-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.