
The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006MJC1WK) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MJC1WK is a combined filter regulator with a built-in reverse (check) valve: it removes water and particulate, regulates downstream pressure, and prevents backflow through the unit. This 200-size version is threaded PT1/8, carries the fine 5 um element, and has a polycarbonate bowl with a manual drain for hand-emptying on a service round. The external round MPa gauge displays the regulated pressure, and the J code means no mounting bracket is included.
This is a genuine AirTAC part. The G series is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and drain type, filter grade, gauge scale and thread (PT standard, G or NPT to order) are all selectable. Flow appears in the catalogue as curves, so we confirm flow and full datasheet figures on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006MJC1WK) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Filtered, regulated air to a solenoid-valve manifold, with the check valve stopping downstream surges from pushing back through the regulator when adjacent sections vent or cycle.
Point-of-use supply for hand tools and small fixtures on an assembly bench: 5 um air, a locked setpoint on the MPa gauge, and manual drain emptied during end-of-shift housekeeping.
Air to a hot-melt or label glue applicator where backflow protection matters: the check valve isolates the regulator and the 5 um element keeps fine contamination out of the applicator valve.
The K code adds a reverse/check valve - useful where a downstream pressure spike must not push back through the regulator. Size the port to the circuit: 1/8 in here for light flows, larger 300/400/600 frames where more air is needed. Manual drain fits regularly serviced cabinets; automatic or differential-pressure drain codes cover unattended spots. Keep the 5 um (W) element where finer filtration matters, or move to the 40 um standard. Gauge options include square styles and psi or bar scales; PT is standard with G and NPT as order options, and a bracket is a separate code. Flow is published as curves rather than one rating, so ask us to confirm sizing against the application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
Flow for the G series is published as curves rather than a single rated figure, so we do not state a number here. Share your supply pressure, set pressure and equipment demand, and we will confirm the flow from the datasheet on request before ordering.
It adds a reverse (check) valve to the unit, so air cannot flow backwards through the filter regulator. Everything else in the code is unchanged: PT1/8 thread, manual drain, 5 um element, no bracket, and an external round gauge scaled in MPa. Order the same code without K if backflow protection is not needed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.