The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006MJF1W) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines filtration and pressure regulation in a single body: air passes through a drain bowl that removes water and particulate, then through the regulator that sets downstream pressure. This GFR20006MJF1W is the compact size 200 unit with a 1/8 inch PT port, a 5 um filtering element (finer than the standard 40 um), a manual drain you operate by hand, an embedded square gauge with MPa scale for set-point reading, and no mounting bracket (J). With a manual drain, the regulator adjusting range is 0.05-0.9 MPa (7-130 psi); maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The polycarbonate bowl suits this 200 size.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with a choice of port sizes, PT, G (BSPP) or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um elements, gauge options and reverse/check valve. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application before ordering.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006MJF1W) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Point-of-use air prep for a compact clamping cylinder on a bench press: the 5 um element protects the cylinder seals from particulate while the regulator sets consistent clamping pressure and the MPa gauge lets the operator verify the set point.
On a carton-sealing or labelling machine, this 1/8 inch filter regulator feeds small air actuators with clean, regulated air, with the manual drain emptied during scheduled changeover checks.
Regulated, filtered air for lab benches and small analytical instruments, where the fine 5 um element and a hand-verifiable pressure setting protect sensitive pneumatic components.
Size 200 with a 1/8 inch port is the entry step of the GFR range - choose a larger size (300/400/600) if your line needs higher flow or a bigger port. The 5 um element (W code) is the right pick where downstream valves or instruments tolerate less particulate than the standard 40 um grade. The M drain means you drain the bowl by hand, which suits dry, supervised installations; the J code means no bracket, so specify one if you panel-mount. The F1 gauge gives a square, MPa-scale readout; N versions omit the gauge. Thread is PT as standard, with G and NPT available as order options.
Because AirTAC publishes flow for this series as curves and not as a single rating number, we do not quote a rated flow here. Send us your application details and we will confirm sizing against the datasheet curves before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as performance curves, not as a single rated figure, so we do not state a rated flow number here. Contact us with your application details and we will confirm the appropriate sizing directly from the datasheet before you order.
The M in the code specifies a manual drain: the bowl is emptied by hand, which suits installations that are checked regularly. The GFR200 is also available with a differential-pressure drain (default) or an automatic drain (A). Note the adjusting range differs by drain: manual-drain units adjust 0.05-0.9 MPa (7-130 psi), while automatic and differential-pressure units adjust 0.15-0.9 MPa (20-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.