The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006MLN) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR20006MLN is an AirTAC G-series filter regulator: one body that removes water and particulate from compressed air and then regulates its pressure. This 200-size configuration has a 1/8 in. PT port, a manual-drain polycarbonate bowl, the standard 40 um filter element and the low-pressure regulator type, whose set point can be adjusted up to 0.4 MPa. No gauge is fitted, so it suits panels that read pressure elsewhere. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is offered in 200, 300, 400 and 600 sizes, with automatic, manual or differential-pressure drains, a 5 um element option (suffix W), gauge options, a reverse/check valve (K) and PT, G(BSPP) or NPT threads. Because AirTAC publishes flow as curves rather than a single rating, we confirm the datasheet figures for your application on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006MLN) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Feeding filtered, gently regulated air to air-film conveyance tables where the film must sit well below standard shop settings - the low-pressure type caps the adjustment at 0.4 MPa.
Conditioning supply air for laboratory test benches that run at reduced pressure, with a manual drain suited to regularly attended equipment.
Regulating low-pressure air to small loading cylinders on printing and converting machines where rollers must press lightly against the web.
Size 200 with a 1/8 in. PT port is the compact entry point of the range; step up to 300, 400 or 600 when your line needs larger ports and more flow. Manual drain (M) means someone bleeds the bowl at intervals - choose automatic (A) if the point of use is unattended, or leave the code blank for the differential-pressure default. This unit is the low-pressure type (L), capped at a 0.4 MPa setting, and carries no gauge (N). Thread is PT as standard; G and NPT are orderable options. Flow appears in the catalogue as curves, not one rated number, so ask us to confirm sizing against your flow and pressure targets before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so no one number applies. Send us your inlet pressure, set pressure and required flow, and we will confirm sizing from the datasheet on request.
It selects the low-pressure regulator type, whose set point tops out at 0.4 MPa instead of the standard range. The M is the manual drain and N means no gauge is fitted - all three are choices you can swap when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.