The AirTAC AirTAC GFR200-06 Filter Regulator (GFR20006NW) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006NW is a G-series filter regulator: it removes water and particulate from compressed air and holds a steady downstream pressure in one compact body. This 200-size unit has a 1/8 in PT port, a fine 5 um filter element (the tighter option versus the standard 40 um), a differential-pressure drain, a standard regulating range of 0.15-0.9 MPa (20-130 psi), and no gauge fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is offered in 200, 300, 400 and 600 sizes with a choice of filter grade, drain type, gauge and thread (PT standard, G and NPT as catalogue options). Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing on request.
| Model | AirTAC GFR200-06 Filter Regulator (GFR20006NW) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Conditioning and regulating the shop-air feed to a machining centre's pneumatic tool clamps and chip-clearing jets, with the 5 um element protecting fine metering components.
Supplying clean, regulated air to a pneumatic positioner or I/P-controlled globe valve on a process line, where steady pressure keeps the control loop stable.
Feeding bench-top pneumatic apparatus or test rigs at a set pressure, with fine 5 um filtration keeping moisture and particles out of sensitive fittings.
Start with the port: this unit is 1/8 in PT, the smallest step in the GFR range - if your line needs more flow, the 300, 400 or 600 sizes give larger ports. Choose the 5 um element (this code, suffix W) when downstream equipment needs finer filtration than the standard 40 um. Drain here is differential-pressure (the default); automatic or manual drains are available on other codes. This configuration carries no gauge - gauge codes can be added. Thread is PT as standard; G (BSPP) and NPT are orderable options, and a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the G-series as curves rather than a single rated figure, so we do not quote a number that is not in the datasheet. Tell us your application and we will confirm the flow data and correct sizing from the datasheet on request.
The N in GFR20006NW means no gauge is fitted on this configuration. Other GFR codes are available with the embedded square gauge or an external round gauge in MPa, psi or bar scales - ask us for the right code if you want a pressure indication.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.