verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

AirTAC GFR200-08 Filter Regulator (GFR20008C3W)

The AirTAC AirTAC GFR200-08 Filter Regulator (GFR20008C3W) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$35.47 $40.03Save 11% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR200-08 drain, gauge and thread option on one page All GFR200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR200-08 Filter Regulator (GFR20008C3W)

The GFR20008C3W is an AirTAC G-series filter regulator: a genuine AirTAC part that removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the size 200 unit with a 1/4 in PT port, the fine 5 um filter element (W suffix) for applications where downstream valves, cylinders and instruments need finer protection than the standard 40 um grade, a differential-pressure drain, and a round external pressure gauge scaled in bar.

It handles a maximum working pressure of 1.0 MPa (145 psi), with a regulation range of 0.15-0.9 MPa (20-130 psi) for this differential-pressure drain version, and an operating temperature of -5 to 70 C (non-freezing). The size 200 bowl is PC (polycarbonate). AirTAC builds the same family in sizes 200, 300, 400 and 600; flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

AirTAC GFR200-08 Filter Regulator (GFR20008C3W) Technical Specifications

ModelAirTAC GFR200-08 Filter Regulator (GFR20008C3W)
SeriesGFR200 filter regulator
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR200-08 Filter Regulator (GFR20008C3W)

GFR200G-series filter regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/4" · 5 µm
One size upGFR300
Add lubricationGFC200-08 (two-unit set)

Where the AirTAC GFR200-08 Filter Regulator (GFR20008C3W) Is Used

science

Laboratory instrument air supply

Conditioning the compressed air feeding lab analysers and pneumatic sample-handling fixtures, where the 5 um element protects sensitive instrument circuits from finer particulate.

valve

Paint-spray booth regulator station

Serving the air feed to spray-gun regulators and booth actuation valves in a finishing line, with fine filtration ahead of precision air-valve components.

precision_manufacturing

Assembly cell pneumatic tooling

Mounted at an automated assembly cell's air drop, it filters and regulates supply to pick-and-place cylinders and clamping fixtures, with the bar gauge showing the set pressure.

Is the AirTAC GFR200-08 Filter Regulator (GFR20008C3W) the Right Unit?

Choose this 5 um (W) element over the 40 um standard when the served equipment is sensitive to finer contamination; keep the 40 um grade for general plant-air duty where finer filtration is unnecessary. The port here is 1/4 in PT on the size 200 body - if your flow demand grows, move to size 300 or 400 rather than undersizing.

Drain options in the family are differential-pressure (this code), manual (M) and automatic (A); the differential drain suits steady duty, while automatic suits unattended installations. Gauge: the embedded square gauge is standard, and this code specifies the external round gauge in bar (MPa and psi scales available). Thread is PT as the standard, with G (BSPP) and NPT as orderable catalogue options, and a mounting bracket is included by default. Flow is published as curves, not a single rating - send us your requirements and we will confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR200-08 Filter Regulator (GFR20008C3W) FAQ

AirTAC publishes GFR-series flow as curves rather than a single rated number, so we do not state a figure here. Share your inlet pressure, regulated pressure and demand, and we will confirm the size against the datasheet curves on request before you order.

Only the filter element grade: the W suffix selects the optional 5 um element instead of the 40 um standard, for finer protection of downstream components. Everything else decodes the same - size 200, 1/4 in PT port, differential-pressure drain, round bar-scale gauge, standard regulator type.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR200-08 Filter Regulator (GFR20008C3W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20008C3W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.