The AirTAC AirTAC GFR200-08 Filter Regulator (GFR20008F2) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20008F2 is a G-series filter regulator: it removes water and particulate from compressed air and sets downstream pressure in one body. This 200-size unit has a PT1/4 port, the standard 40 um filtration element, a square pressure gauge on a psi scale, and a differential-pressure drain that vents condensate as the element loads up. With differential-pressure drainage, the adjustment range is 0.15-0.9 MPa (20-130 psi); max working pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part in the GFR200 series, the compact end of the 200/300/400/600 size range, with a PC (polycarbonate) bowl on this size. Gauge scales in MPa and bar, 5 um filtration, other drain types, and G (BSPP) or NPT threads are catalogue options across the series. Flow is published as curves rather than a single rating, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFR200-08 Filter Regulator (GFR20008F2) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-08 (two-unit set) |
Filters and regulates the 1/4 inch air feed to a control panel's solenoid valves and pilot circuitry, with the psi gauge matching US-style plant pressure settings.
Conditions air at individual workbench drops on an assembly line, giving operators a filtered supply at a set psi for hand-held pneumatic tools and small actuators.
Feeds filtered, regulated air to dock-levelling and trailer-related pneumatic controls, where the standard 40 um element handles general plant air protection.
This code gives you the standard configuration of the 200-size filter regulator in psi-reading form: 40 um element, square psi gauge, differential-pressure drain, PT1/4 thread, bracket included. Step to the W grade only if your application needs 5 um air; move up a size (300/400/600) if flow demand outgrows the 1/4 inch port. MPa and bar gauge scales, automatic (A) and manual (M) drains, and G (BSPP) or NPT threads are all orderable options. Flow for this series is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
There is no single rated-flow number to quote: AirTAC publishes flow for the G-series as curves. Share your supply pressure, set pressure and air demand and we will confirm the datasheet flow data for this 200-size, 1/4 inch unit on request before you order.
F2 means the square gauge is fitted with a psi scale (F1 would be MPa, F3 bar). Everything before it is standard for this configuration: 200 size, 1/4 inch PT port, 40 um default element, and the default differential-pressure drain, since no A or M drain letter appears in the code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.