The AirTAC AirTAC GFR200-08 Filter Regulator (GFR20008F2T) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20008F2T is a G-series filter regulator in the NPT-threaded version, marked by the trailing T: it removes water and particulate from compressed air and regulates downstream pressure in one body. This 200-size unit carries a 1/4 inch NPT port, the standard 40 um filtration element, a square gauge on a psi scale, and a differential-pressure drain. With differential-pressure drainage the adjustment range is 0.15-0.9 MPa (20-130 psi); max working pressure is 1.0 MPa (145 psi). Operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part in the GFR200 series, the smallest of the 200/300/400/600 size steps, with a PC (polycarbonate) bowl on this size. The PT-threaded standard and G (BSPP) options cover the other thread needs, and psi, MPa or bar gauge scales, 5 um filtration and other drain types are catalogue options across the series. Flow is published as curves rather than a single rating, so we confirm datasheet figures for your application on request.
| Model | AirTAC GFR200-08 Filter Regulator (GFR20008F2T) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-08 (two-unit set) |
Drops filtered, regulated air from a US plant's NPT-threaded distribution headers to machine stations, with the psi gauge reading the pressures maintenance staff already work in.
Feeds a maintenance shop's bench regulators and test rigs on 1/4 inch NPT plumbing, giving a filtered supply for repairing and proving-out pneumatic assemblies.
Sets and holds working pressure on a pneumatic component test stand fed with NPT fittings, with the 40 um element guarding the stand's valves and gauges from plant-air debris.
Choose this code when your piping is NPT: the trailing T orders the 200-size, 1/4 inch filter regulator with an NPT1/4 port instead of the PT standard, with the standard 40 um element, square psi gauge, differential-pressure drain and bracket included. Specify the W grade for 5 um filtration if your circuit needs finer air, or step up to 300/400/600 sizes as flow demand grows. MPa and bar gauge scales, automatic (A) and manual (M) drains, and the PT or G (BSPP) thread variants are orderable options. Flow for this series is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Yes. Flow for this series is published as curves rather than as a single rated figure, so we do not state one number. Send your inlet pressure, set pressure and required air consumption and we will confirm the datasheet flow figures for this 200-size, NPT1/4 unit on request.
Only the thread. The trailing T orders the 1/4 inch port in NPT for North American piping; the plain code is the PT-threaded standard, and a G variant in BSPP is also a catalogue option. Filtration (40 um), drain (differential-pressure), gauge (square, psi) and size are identical.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.