The AirTAC AirTAC GFR200-08 Filter Regulator (GFR20008JC1) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR20008JC1 is an AirTAC G-series filter regulator configured without a mounting bracket and with an external round gauge on the MPa scale. It filters water and particulate from compressed air and regulates downstream pressure in one body: a size 200 unit on a PT1/4 (PT thread, 1/4 in.) port, standard 40 um element, polycarbonate bowl with differential-pressure drain, and an adjust range of 0.15-0.9 MPa (20-130 psi). Working pressure is up to 1.0 MPa (145 psi) and temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series runs sizes 200 to 600 with ports from 1/8 in. to 1 in., and offers bracket-included or bracketless (J) builds, gauge-less (N) or round/square gauges in MPa, psi or bar scales, 40 um or 5 um (W) elements, and G (BSPP) or NPT threads instead of the standard PT. Flow is published as curves rather than a single rating, so we confirm sizing and the datasheet on request.
| Model | AirTAC GFR200-08 Filter Regulator (GFR20008JC1) |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/4" · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-08 (two-unit set) |
Conditions the 1/4 in. branch that feeds the pneumatic chuck and tool-change cylinders on a CNC machining centre, with the MPa round gauge matching the readings the maintenance team already uses.
Supplies the diverter and stopper cylinders along a parcel sortation conveyor, delivering strained, regulated air to the valves that throw parcels between lanes.
Sits in the supply line to an industrial robot's gripper circuit, letting the integrator set a fixed working pressure for part handling without adding a separate filter upstream.
The J in the code means no mounting bracket is fitted, so plan to mount the unit directly on the machine or panel-connected pipework; the same size is available with a bracket by dropping the J. The C1 gauge code gives an external round gauge reading in MPa; square embedded gauges, psi or bar scales, and gauge-less versions are alternatives. Choose the drain to suit the duty: differential-pressure drain here (0.15-0.9 MPa / 20-130 psi adjust), manual drain for a wider 0.05-0.9 MPa (7-130 psi) window, automatic drain for unattended bowls.
Stay at 40 um for general supply or order the W suffix for a 5 um element, and select G (BSPP) or NPT thread at order time if PT does not suit the installation. Flow for G-series units is published as curves, not a single rating, so ask us to check your flow and pressure points against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no one rated number to quote. Give us your application flow and working pressure and we will confirm the correct size from the datasheet on request.
J means this unit is supplied without a mounting bracket (omit the J for a bracket-included build), and C1 means an external round gauge with the MPa scale is fitted. Bar (3) or psi (2) scales, a square embedded gauge (F), or no gauge (N) are catalogue alternatives.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.