The AirTAC Airtac GFR Filter Regulator GFR200C06JC1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR200C06JC1K is an AirTAC G-series filter regulator: filtration and pressure regulation in one body, for compressed air only. This configuration is the size 200 unit with a 1/8 in. PT port, the standard differential-pressure drain, the standard 40 um element, an external round pressure gauge reading in MPa and a reverse (check) valve fitted (K); the J code means it is supplied without a mounting bracket. Inlet pressure is rated to 1.0 MPa (145 psi), the setpoint adjusts from 0.15 to 0.9 MPa (20-130 psi) and the polycarbonate bowl suits -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the GFR family, offered in sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., and options that include drain type, 5 um filtration, gauge type and scale, G (BSPP) or NPT threads and the reverse valve. Flow is published by AirTAC as curves rather than one rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | Airtac GFR Filter Regulator GFR200C06JC1K |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Setting working pressure to clamp cylinders on a CNC fixture: the MPa round gauge gives a direct local reading and the fitted check valve matches circuits that call for one.
Filtering and regulating supply to a bank of small actuators on an electronics assembly module, where one 1/8 in. unit conditions the branch before it is distributed to each station.
A point-of-use filter regulator at the maintenance bench for air tools and blow guns, keeping line pressure at the set value with a visible gauge for quick checks.
Decodable choices here: port step (1/8 in. on this 200 body; 300/400/600 give larger ports for higher flow), drain type (differential-pressure standard, A automatic, M manual - the manual variant widens the adjustment range to 0.05-0.9 MPa), element grade (40 um standard, W for 5 um), gauge type and scale, thread (PT standard, G and NPT orderable), bracket (J omits it) and the K reverse valve, which is fitted on this unit. Since AirTAC publishes flow as curves and not a single rating, send us your flow and pressure requirements and we will confirm sizing against the datasheet before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
There is no single rated flow figure for GFR units - AirTAC publishes performance as flow curves. Tell us your application flow and pressure and we will confirm the datasheet figures and check that the 200 size suits the duty before you order.
K specifies that a reverse (check) valve is fitted in this filter regulator. Order the same code without K when your circuit does not call for one. Everything else in the decode is identical: 1/8 in. PT port, 40 um element, differential-pressure drain, round MPa gauge and no bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.