The AirTAC AirTAC GFR300-10 Filter Regulator (GFR30010AJNWK) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR30010AJNWK is an AirTAC GFR-series filter regulator that filters and regulates in a single body. This 300-size unit carries a PT3/8 port, an A-code automatic drain that discharges condensate on its own, the W-coded 5 um fine filtration element, and a K-code check valve that holds downstream pressure if the upstream supply falls. No gauge is fitted.
This is a genuine AirTAC part in the 200/300/400/600 G-series line, also available in other ports and threads (G and NPT as catalogue options), other drain types, the 40 um standard element and an optional gauge. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.
| Model | AirTAC GFR300-10 Filter Regulator (GFR30010AJNWK) |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT3/8" · 5 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-10 (two-unit set) |
Supplies the pallet-clamp circuit on a CNC machining centre; the check valve maintains clamping pressure if the shop-air supply momentarily drops.
Feeds the hold-down cylinders on a pneumatic press, keeping the regulated clamping force locked in through supply fluctuations.
Runs the gripper actuators on an electronics assembly cell, with the 5 um element keeping fine particulate out of the small valve package.
This is the fine-filtration, hold-pressure version of the 300 size: the PT3/8 port suits lines with several consumers, the 5 um element protects sensitive downstream equipment, and the check valve is the reason to pick this over GFR30010AJNW when a momentary supply drop must not release the downstream circuit. Automatic drain keeps the bowl clear without operator visits.
Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering. The thread is standard PT; G (BSPP) and NPT are order options, and the J code means no mounting bracket is supplied.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
There is no single rated flow number to quote: AirTAC publishes flow for this series as curves. Share your line pressure and air consumption and we will confirm the sizing from the datasheet on request.
The K code adds a reverse/check valve, so downstream pressure is held when upstream supply falls. Everything else decodes the same: 300 size, PT3/8 port, automatic drain, 5 um element, no gauge, standard PT thread. We can help you decide if the check valve suits your circuit on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.