The AirTAC AirTAC GFR300-10 Filter Regulator (GFR30010F1K) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR30010F1K is a G-series filter regulator fitted with a reverse (check) valve, which holds the downstream setting if upstream supply is interrupted. It filters and regulates in one body with the standard 40 um element, a differential-pressure drain on the polycarbonate bowl, and the embedded square gauge in MPa. The 3/8 in PT port matches the 300 size, and the regulator adjusts 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part in the GFR300 series, offered in 200 to 600 sizes with G/NPT/PT threads and automatic or manual drain options. The K check-valve variant is a catalogue choice for circuits that must hold pressure upstream. Flow figures appear only as curves, so we confirm datasheet values on request.
| Model | AirTAC GFR300-10 Filter Regulator (GFR30010F1K) |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-10 (two-unit set) |
Keeps a regulated setpoint on a valve-manifold branch even when the upstream supply is shut, so actuator positions do not drift during maintenance on the main line.
Maintains clamp pressure on a machining fixture while the upstream air is bled or switched, with the check valve preventing backflow out of the circuit.
Supplies filtered, regulated air to interlocked guarding actuators on a press line, holding the setpoint through brief supply interruptions and reading it on the MPa gauge.
Specify K when the circuit must keep its regulated pressure during a supply drop - otherwise the same unit without K, the GFR30010F1, is the choice. Port sizing follows your piping: 3/8 in on the 300 body sits between the 1/4 in (200) and 1/2 in (400) steps. This unit uses the 40 um standard element; the 5 um W grade exists for finer circuits. The embedded square MPa gauge saves panel space versus the round external option. PT is standard, G and NPT are catalogue options, and the bracket is included.
Flow is published as curves, not a single rating, so ask us to confirm sizing for your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
We do not quote a single rated flow because AirTAC publishes this series as flow curves. Give us your operating pressure and demand and we will confirm the datasheet figure for this 3/8 in, 300-size unit with check valve on request.
K means a reverse (check) valve is fitted, so downstream pressure is held if the upstream supply drops. If your circuit does not need that hold function, the GFR30010F1 without K is identical otherwise: 40 um element, 3/8 in PT, MPa square gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.