verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

AirTAC GFR400-10 Filter Regulator (GFR40010JN)

The AirTAC AirTAC GFR400-10 Filter Regulator (GFR40010JN) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$56.15 $61.23Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-10 drain, gauge and thread option on one page All GFR400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR400-10 Filter Regulator (GFR40010JN)

The AirTAC GFR40010JN is a G-series filter regulator that removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 400 configuration has a PT 3/8 in port, the standard 40 um filter element, a differential-pressure drain in the polycarbonate bowl, and no pressure gauge (code N). The J code means it ships without a mounting bracket, keeping the footprint minimal where an existing panel already carries the instrumentation.

It is a genuine AirTAC part from the G series, offered in sizes 200, 300, 400 and 600 with 1/8 in to 1 in ports and PT, G (BSPP) or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator covers 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain, and the temperature range is -5 to 70 C. Flow figures are published as curves rather than a single rating; ask us and we will confirm the flow and datasheet values for your application on request.

AirTAC GFR400-10 Filter Regulator (GFR40010JN) Technical Specifications

ModelAirTAC GFR400-10 Filter Regulator (GFR40010JN)
SeriesGFR400 filter regulator
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR400-10 Filter Regulator (GFR40010JN)

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the AirTAC GFR400-10 Filter Regulator (GFR40010JN) Is Used

conveyor_belt

Packaging line actuator supply

Filters and regulates the air feeding conveyor stop-gates, pushers and carton-forming cylinders on a packaging line, where general-grade 40 um filtration is sufficient.

factory

Plant air drop for assembly cells

Installed at the air drop point of an assembly workstation to give operators a set, stable working pressure for air tools and clamping fixtures.

settings_input_component

Control panel air interface

Used where a pre-assembled control panel already has its own gauges, so the filter regulator is specified without one to avoid duplicate instrumentation.

Is the AirTAC GFR400-10 Filter Regulator (GFR40010JN) the Right Unit?

Choose size 400 with its 3/8 in port when your air demand exceeds what a size 300 unit serves comfortably, or drop to size 200/300 for lighter circuits. The standard 40 um element suits general plant air; specify the W suffix for a 5 um element where cleaner air is required. This version carries no gauge, so add an external round gauge in MPa, psi or bar scale from the catalogue options if local pressure indication is needed. PT is the standard thread, with G and NPT variants available to order, and a bracket can be added if you need panel mounting.

AirTAC does not publish a single rated flow figure for this family, only curves. Contact us with your application details and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR400-10 Filter Regulator (GFR40010JN) FAQ

AirTAC publishes flow for the GFR400 series as curves rather than a single rated number, so we do not state one here. Give us your supply pressure and required air demand and we will confirm the flow and datasheet figures for this model on request.

Yes. The N in this code simply means no gauge is fitted; catalogue options include an external round gauge with MPa, psi or bar scale. For finer air, the W suffix selects a 5 um element instead of the standard 40 um grade fitted here.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR400-10 Filter Regulator (GFR40010JN)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010JN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.