The AirTAC AirTAC GFR400-10 Filter Regulator (GFR40010MF1) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR40010MF1 is a genuine AirTAC GFR400-series filter regulator that removes water and particulate from compressed air and regulates downstream pressure in one body. This 400-size unit has a 3/8 in PT port, a manual drain bowl, the standard 40 um filter element, and the square embedded pressure gauge with an MPa scale, so one connection gives you clean air at a set pressure.
It is a genuine AirTAC part from the G-series range, which spans 200, 300, 400 and 600 sizes with automatic, manual or differential-pressure drains, a 5 um element option and G or NPT thread variants. Rated flow is published as curves rather than a single figure, so we confirm the datasheet and flow numbers for your application on request.
| Model | AirTAC GFR400-10 Filter Regulator (GFR40010MF1) |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT3/8" · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-10 (two-unit set) |
Point-of-use conditioning for a robotic assembly cell: the GFR40010MF1 filters water and chips from the plant air header and holds a steady regulated pressure to the cell's valve manifold, with the MPa gauge giving the maintenance team a clear setpoint reading at the station.
On a cartoning or case-sealing conveyor line, this filter regulator conditions the 3/8 in branch feeding pneumatic pushers and clamps. The manual drain is opened at shift start and end, and the regulator keeps actuator speed consistent as the header pressure wanders.
Installed ahead of loom or knitting-machine air jets and cylinders, the unit strips condensate and 40 um particulate from a humid mill air supply and regulates it to the machine's specified working pressure, with the manual drain serviced during scheduled stops.
At 400 size with a 3/8 in PT port, this model sits in the upper mid-range of the G-series; step up to 600 or down to 300 depending on the flow your line needs. The manual drain means an operator opens the bowl drain during checks - choose automatic if nobody is regularly at the machine. The 40 um element handles general plant air; pick the W variant for 5 um protection. Gauge scale is MPa here, with psi and bar alternatives available, and the trailing thread code can be G (BSPP) or T (NPT) instead of the PT standard. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR400 series as characteristic curves, not as a single rated number, so we do not quote one figure here. Tell us your line pressure and downstream demand and we will confirm the datasheet and flow curve for this 3/8 in model on request.
The M in the code means the bowl drain is opened by hand - ideal where an operator already visits the machine daily. The same 400-size GFR is also available with an automatic or differential-pressure drain, and note that the manual-drain version carries a wider regulator adjustment range starting lower: 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) for the auto and differential versions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.