The AirTAC AirTAC GFR400-15 Filter Regulator (GFR40015MF1WK) is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR40015MF1WK is a filter regulator that cleans compressed air to 5 um and regulates downstream pressure in a single body, with a built-in check (reverse) valve that permits back-flow from the outlet side when supply pressure is removed. This 400-size configuration has a PT 1/2 in port, a polycarbonate bowl with manual drain, the fine W-grade element, and an embedded square gauge scaled in MPa. Manual drainage gives a regulator set range of 0.05-0.9 MPa (7-130 psi); maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the G-series, which runs from size 200 to 600 and offers automatic or differential-pressure drains, the 40 um standard element, psi or bar gauge scales, G (BSPP) or NPT threads, and bracket options. Because rated flow is published only as curves, we will confirm the datasheet figures for your sizing question on request.
| Model | AirTAC GFR400-15 Filter Regulator (GFR40015MF1WK) |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-15 (two-unit set) |
Regulates and finely filters air to robot grippers on a weld line, with the check valve preserving gripper pressure if the cell supply is interrupted.
Provides clean, settable air to hydraulic-boost clamps on a test bench, letting engineers read MPa directly and bleed the manual bowl between runs.
Guards seal-bar and forming pneumatics on a packaging machine with 5 um air while the check valve cushions the circuit against supply dips.
Choose this code when you need three things at once: the 400-size PT 1/2 in port for heavier air demand, the 5 um element (W) for finer filtration, and the K check valve to hold downstream conditions during supply dropouts. Drainage is manual here, with the 0.05-0.9 MPa (7-130 psi) set range; unattended installs should step to automatic or differential-pressure drain codes, which set 0.15-0.9 MPa (20-130 psi). Gauge scale can be ordered in psi or bar, threads as PT (standard) or G (BSPP)/NPT to order, and a bracket is included by default. Flow appears in the catalogue as curves, not a single rating, so ask us to check the datasheet against your demand before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Give us your flow demand and operating pressure and we will confirm the datasheet figures for this 400-size, PT 1/2 in unit on request.
W selects the fine 5 um filter element over the standard 40 um grade, and K means a check (reverse) valve is fitted so downstream air can flow back when the supply shuts off. The M indicates a manual bowl drain, which sets the regulator range at 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.