verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K)

The AirTAC AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K) is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$73.15 $78.65Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K)

The AirTAC GFR series combines a compressed-air filter and a pressure regulator in one body: water and particulate are removed in the drain bowl, and the downstream pressure is set to the level your equipment needs. This GFR40015MJF1K is the 400 size with a 1/2 in PT thread, a manual drain bowl in polycarbonate, the standard 40 um filter element, an embedded square gauge scaled in MPa, and a reverse (check) valve fitted so downstream pressure is retained if the upstream supply drops. Maximum inlet pressure is 1.0 MPa (145 psi) and the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) with this manual-drain version. Operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes, with G, NPT or PT threads, automatic, manual or differential-pressure drains, 5 um (W) or standard 40 um elements, gauge and bracket options, and the check-valve (K) variant. Flow for this model is published as a curve rather than a single rated figure; ask us and we will confirm the datasheet figures for your application on request.

AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K) Technical Specifications

ModelAirTAC GFR400-15 Filter Regulator (GFR40015MJF1K)
SeriesGFR400 filter regulator
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K)

GFR400G-series filter regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT1/2" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-15 (two-unit set)

Where the AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K) Is Used

precision_manufacturing

Pneumatic clamping on welding fixtures

Supplies filtered, regulated air to clamp and hold-down cylinders on a fixture line. The fitted check valve keeps the set clamping pressure in the circuit if the upstream supply dips during a press cycle.

valve

Machine-drop air preparation

Installed at the 1/2 in drop feeding a machine's directional valve stack, cleaning line-scale moisture and particles out of the plant air and setting the supply pressure the valve stack was sized for.

factory

Packaging machinery air supply

Feeds carton sealers and case packers on a packaging line, where the operator reads the MPa gauge and dials the working pressure the machine's cylinders and actuators need.

Is the AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K) the Right Unit?

Step up from a 300 to this 400 body when your line is plumbed in 1/2 in pipe and your compressor-side flow demand sits above what the smaller ports serve; the 600 size is the next step for 3/4 in and 1 in headers. The M in the code means manual drain: someone vents the bowl by hand, which suits positions that are checked daily. Choose automatic (A) for unattended drains and the default differential-pressure drain where you want automatic draining driven by the pressure drop across the element. This unit carries the standard 40 um element; order the W suffix for 5 um when finer protection is needed. The embedded square gauge reads in MPa; psi or bar scales and an external round gauge are catalogue options. PT is the standard thread and G (BSPP) or NPT versions can be ordered as specifications. The J suffix here means the mounting bracket is not included - order a bracket if you panel-mount. Because flow is published as curves and not as one rated number, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K) FAQ

AirTAC publishes flow for this model as a curve across pressures, not as a single rated figure, so we do not quote one number. Tell us your working pressure and air demand and we will confirm the datasheet flow figures for your operating point on request before you order.

The K means a reverse (check) valve is fitted, so downstream pressure is held when upstream supply falls - useful on clamping and holding circuits. The M means the bowl is drained by hand, and with manual drain the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Versions without K omit the valve, and A or blank drain codes give automatic or differential-pressure draining.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR400-15 Filter Regulator (GFR40015MJF1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40015MJF1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.