AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um

The AirTAC AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$35.18 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um

The AirTAC GFR200-06LW is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one compact body. This unit is built in the 200 size with a PT 1/8 in port, the 5 um filter element (the W grade, finer than the 40 um standard), a differential-pressure drain, and the low-pressure regulator type. A round gauge scaled in psi is fitted, the mounting bracket is included, and the polycarbonate bowl lets you check the condensate level at a glance. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR series spans the 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, drain choices (differential-pressure, automatic or manual), 40 um or 5 um filtration, standard or low-pressure regulation, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um Technical Specifications

ModelAirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um
SeriesGFR200 filter regulator
Port sizePT1/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um

GFR200G-series filter regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/8" · 5 µm
One size upGFR300
Add lubricationGFC200-06 (two-unit set)

Where the AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um Is Used

precision_manufacturing

CNC fixture clamping

Filtered, regulated air to pneumatic clamps on a machining cell, where condensate and fine particles in the supply would upset repeatable clamping.

factory

Paint-line spray guns

Clean, pressure-stable air to spray guns in a finishing booth, with 5 um filtration catching fine particles before they reach the nozzle.

conveyor_belt

Packaging-line diverters

Filter-regulated air for diverters and pushers on a packaging conveyor, keeping actuator pressure steady through shift changes.

Is the AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um the Right Unit?

Start with size and port: 200 through 600, with ports from 1/8 in to 1 in, stepped against the flow your line needs. Then drain type: differential-pressure (this unit), automatic for unattended draining, or manual for infrequent servicing. Filter grade is 40 um standard or 5 um (this unit's W code) where finer downstream protection matters. On regulated units you also choose standard or low-pressure type, gauge style (embedded square or external round) with scale MPa, psi or bar, thread (PT standard, G or NPT to order), and whether a bracket is fitted - this one includes it. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um FAQ

AirTAC publishes GFR flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet flow curves against your required flow before you order.

The W code selects the 5 um element instead of the 40 um standard. Choose 5 um where downstream valves, cylinders or instruments need finer protection; 40 um suits general plant air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR200-06LW Filter Regulator, PT 1/8 in, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR20006LC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.