The AirTAC AirTAC GR200-08 Pressure Regulator (GR20008LF1) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The AirTAC GR20008LF1 is a compressed-air pressure regulator from the G series, sized 200 with 1/4 in. PT ports. It is the low-pressure (L) type, so its output is adjustable up to 0.4 MPa for circuits that must not run at full line pressure. It carries a square embedded pressure gauge on an MPa scale, includes a mounting bracket, and is rated to 1.0 MPa (145 psi) maximum inlet pressure with an operating temperature of -20 to 70 C.
This is a genuine AirTAC part. The GR series is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in., a choice of gauge (round or square; MPa, psi or bar scale), a low-pressure option, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request before you order.
| Model | AirTAC GR200-08 Pressure Regulator (GR20008LF1) |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/4" (PT thread) |
| Regulating range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure type | Low-pressure type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| L | Low-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/4" · 0.05 - 0.4 MPa (7 - 58 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Regulate the low-pressure air feed to pnuematic guides and thread tensioners on a textile machine, with the MPa gauge matching the machine's pressure schedule.
Supply gently regulated air to vacuum generators and small gripper cylinders on an electronics assembly module where low set points protect delicate parts.
Feed low-pressure purge air to instrument enclosures and ventilation-assist manifolds in a process plant, held well below the main header pressure.
This code fixes the key choices: size 200 with 1/4 in. PT ports, low-pressure (L) type with adjustment up to 0.4 MPa, and a square embedded gauge on an MPa scale. If your line needs higher set points, the standard GR type adjusts 0.05-0.9 MPa; if you prefer psi or bar readout or a round external gauge, those are separate order codes. PT thread is the standard; G (BSPP) and NPT are catalogue options, and a no-bracket (J) version exists.
For sizing, work from the port step: 200/1/4 in. suits light branch lines, while larger sizes carry more flow. Flow for this series is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC publishes GR series flow as curves rather than a single rated number, so there is no one figure we can quote. Tell us your inlet pressure and required downstream flow and we will confirm the sizing from the datasheet curves on request.
L is the low-pressure type, which limits the regulated output to up to 0.4 MPa instead of the standard 0.05-0.9 MPa range. F1 specifies the square embedded pressure gauge on an MPa scale; round gauges and psi or bar scales are separate order codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.