verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR200 · Air Pressure Regulator

AirTAC GR200-08 Pressure Regulator (GR20008LF3K)

The AirTAC AirTAC GR200-08 Pressure Regulator (GR20008LF3K) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketFixing bracket included
$42.27 $47.01Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GR200-08 type, gauge and bracket option on one page All GR200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GR200-08 Pressure Regulator (GR20008LF3K)

The GR series is AirTAC's air pressure regulator family: it reduces and holds a steady downstream pressure from a compressed-air supply, with no filtration and no bowl anywhere in the body. GR20008LF3K is the size 200 unit with a PT1/4 taper port. The L marks the low-pressure type, whose set pressure tops out at 0.4 MPa; the K marks a built-in reverse (check) valve that lets downstream air vent back upstream when supply is cut; the J means no mounting bracket is supplied; and F3 gives an embedded square pressure gauge scaled in bar.

This is a genuine AirTAC part. The GR family is rated for compressed air at up to 1.0 MPa (145 psi) inlet and -20 to 70 C, and comes in sizes 200, 300, 400 and 600 for larger ports and more flow, with optional brackets, square or round gauges scaled in MPa, psi or bar, a reverse-valve option, and G (BSPP) or NPT threads as catalogue alternatives to standard PT. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and the datasheet for your application.

AirTAC GR200-08 Pressure Regulator (GR20008LF3K) Technical Specifications

ModelAirTAC GR200-08 Pressure Regulator (GR20008LF3K)
SeriesGR200 pressure regulator
Port sizePT1/4" (PT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, bar scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GR200-08 Pressure Regulator (GR20008LF3K)

GR200G-series pressure regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/4" · 0.05 - 0.4 MPa (7 - 58 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GR200-08 Pressure Regulator (GR20008LF3K) Is Used

tune

Pneumatic press clamping

Set a gentle, repeatable holding pressure on the air line feeding a benchtop pneumatic press that clamps workpieces during drilling or riveting operations.

science

Laboratory instrument air

Regulate shop air down to a low, stable level for lab apparatus such as pneumatic sample conveyors or instrument purge and actuation lines.

factory

Packaging line actuators

Hold a reduced set pressure on the cylinders of a carton-forming or labelling station where full header pressure would slam the mechanisms.

Is the AirTAC GR200-08 Pressure Regulator (GR20008LF3K) the Right Regulator?

Match size and port to the line: this size 200 unit carries a PT1/4 port, while 300/400/600 step up in port and capacity - check the step against your flow curve. The L in this code means the low-pressure type, regulating up to 0.4 MPa; if you need the full standard GR range of 0.05-0.9 MPa (7-130 psi), order a code without the L. Choose the gauge scale you want (square or round, MPa, psi or bar), decide whether the reverse/check valve (K) is needed, and pick PT as standard or G/NPT as ordered thread options; J means no bracket. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

AirTAC GR200-08 Pressure Regulator (GR20008LF3K) FAQ

AirTAC publishes GR performance as flow curves rather than a single rated figure, so we do not quote one number here. Send us your inlet pressure, set pressure and required flow, and we will confirm sizing against the datasheet curves on request.

L marks the low-pressure type, whose regulated set pressure tops out at 0.4 MPa instead of the standard GR range of 0.05-0.9 MPa. F3 means the embedded square gauge is scaled in bar; C codes give round gauges and the digits 1, 2 and 3 select MPa, psi or bar.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GR200-08 Pressure Regulator (GR20008LF3K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR20008LF3K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.