The AirTAC AirTAC GR600-20 Pressure Regulator (GR60020F3) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT3/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
GR60020F3 is an AirTAC GR-series air pressure regulator for compressed air only. The 600 size carries a 3/4 in PT port, and this configuration is fitted with the embedded square pressure gauge on a bar scale. Outlet pressure is set anywhere in the 0.05-0.9 MPa (7-130 psi) adjustment range, with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -20 to 70 C.
This is a genuine AirTAC part from the GR series, which runs from size 200 to 600 with ports from 1/8 to 1 in and PT, G or NPT threads. GR regulators have no bowl, no filter and no lubricator, and are noted for low pressure loss; a mounting bracket can be fitted and panel mounting is possible. Flow is published as curves rather than one rated figure, so ask us to confirm sizing figures from the datasheet for your application.
| Model | AirTAC GR600-20 Pressure Regulator (GR60020F3) |
|---|---|
| Series | GR600 pressure regulator |
| Port size | PT3/4" (PT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR600 | G-series pressure regulator, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR600 · PT3/4" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size down | GR400 |
| Line order | Filter first, then regulator, then lubricator |
Regulates supply air to the actuation circuits on a truck tail-lift or tipper body, where the vehicle gauge standard is bar.
Supplies an air-knife drying or blow-off station on a washdown line at the reduced pressure the nozzle layout was designed around.
Feeds pneumatic hand tools and clamps at an assembly workbench from the shop-air ring main, with the bar gauge read at a glance by operators.
Choose the GR size by the air your circuit consumes: 200 through 600 step up both the port and the flow capacity, and this 600 unit has a 3/4 in PT port. PT is the standard thread, with G (BSPP) and NPT available as catalogue options to order. Gauge choices are the embedded square gauge or an external round gauge on MPa, psi or bar scales - this code carries the square gauge with a bar scale, and no reverse/check valve is fitted. The standard (non-L) type covers the full 0.05-0.9 MPa (7-130 psi) setting range.
Flow is published as curves, not a single rated figure, so send us your line pressure and air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC publishes GR flow as performance curves rather than a single rated figure, so no one flow number applies here. Tell us your inlet pressure and the air your application needs, and we will confirm the sizing from the datasheet on request.
Yes. PT is the standard thread on the GR60020F3, and G (BSPP) and NPT are catalogue options ordered under the matching suffix. State the thread you need with your order, and also note that psi or MPa gauge scales and an external round gauge are available on other codes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.