The AirTAC GC200-08 AirTAC F.R.L. Combination, PT1/4, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC200-08 is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembly: a separate air filter, a pressure regulator and an oil-mist lubricator. This configuration is size 200 with PT1/4 (1/4 in) PT ports, a 40 um standard filter element and a manual drain on the filter bowl, so an operator drains accumulated water by hand as part of routine checks. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and the fitted round gauge reads in psi so downstream pressure can be set and monitored directly.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, thread options (PT standard, G and NPT to order), manual, automatic or differential-pressure drains, a 5 um (code W) filter element, gauge style and scale, and a reverse/check valve option. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request.
| Model | GC200-08 AirTAC F.R.L. Combination, PT1/4, Manual Drain |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Installed at the point where the plant air main drops down to a production cell, the GC200-08 removes water and particulate, sets a stable regulated pressure and adds oil mist for the air tools and cylinders served by that drop.
Mounted on the supply line feeding conveyor drive cylinders and product stoppers, this combination keeps the line's actuation pressure set at the required level, filters out pipe scale and condensate, and lubricates the cylinders in daily service.
Placed upstream of a pneumatic control panel or valve manifold, the unit protects the downstream valves with filtered, regulated air and supplies oil mist where lubricated actuation is specified, with the psi gauge making setpoints easy to verify.
Start with the port step: size 200 with 1/4 in PT ports suits lines where the required air flow falls in the 200-size band - match the size to your flow demand, since larger sizes (300/400/600) carry larger ports and more flow. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering. This unit has a manual drain, which suits installations where an operator is already on site; choose the automatic or differential-pressure drain variants if the bowl should be emptied without manual attention. The 40 um standard element covers general-purpose water and particulate removal; specify the 5 um (W) option where finer filtration is needed. The fitted round gauge reads in psi; embedded square gauges and MPa or bar scales are alternatives. PT is the standard thread, with G (BSPP) and NPT available as order options, and a mounting bracket is included.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated number, so there is no one figure we can quote for this model. Tell us your line pressure, set pressure and air consumption, and we will confirm the datasheet curve and check the sizing for your application before you order.
This configuration has a manual drain, meaning water collected in the filter bowl is released by hand during routine checks - simple and reliable where an operator is regularly present. If the unit will sit where nobody drains it routinely, choose the automatic or differential-pressure drain variants of the same series instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.